RUB » Physics » The Faculty » Chairs and Working Groups » EP1 » PANDA FEMC Production Database

Show Hamamatsu Avalanche Photo Diode 1912021211 - Archived data from Wed, 07. October 2020 12:26:24 CEST


This is all the information about APD 1912021211. If it is wrong, edit the data.

Subdetector specification:  
Serial: 1912021211
Type: Hamamatsu Avalanche Photo Diode
Detector: assigned to 1912021211/2703030226
Unit: unassigned
Preamp: 0
Current location: Bochum
   
Installation information:  
Label: blue
   
Manufacturer information:  
Wafer position: C12
Break-through voltage: 408 V
Voltage for Gain 100 (T=+25°C): 379.7 V
Dark current: 8 nA
   
Screening Logistics:  
Available: No
Storage Box: 257
Position in Box: 34
EP1 batch: none
EP1 batch after irradiation: none
   
Shipment:  
Grid number: none
Position in grid: none
Arrival for irradiation: none
Sent for analysis after irradiation: none
Return for assembly: none
   
Irradiation:  
Date: none
Dose used: none
Temperature: none
Position: none
Bias voltage: none     
   
Annealing:  
Date: none
Temperature: none
Duration: none
   
Measurement results:  
Voltage for Gain 100: T = +20 °C: 379.9931978 V     T = -25 °C: 344.7545959 V
Voltage for Gain 150: T = +20 °C: 387.8223997 V     T = -25 °C: 352.0857974 V
Voltage for Gain 200: T = +20 °C: 392.1712985 V     T = -25 °C: 356.2209223 V
Gain/Voltage slope at M = 100: T = +20 °C: 4.619568448 V-1     T = -25 °C: 5.071204827 V-1
Gain/Voltage slope at M = 150: T = +20 °C: 9.181796707 V-1     T = -25 °C: 9.441818439 V-1
Gain/Voltage slope at M = 200: T = +20 °C: 14.27747187 V-1     T = -25 °C: 14.81247982 V-1
Break-through voltage: T = +20 °C: 407.5580358 V     T = -25 °C: 371.4372057 V
   
Notes:


Version history

Time Author Change comment
05. Feb 2021 11:21:25 CET jreher Updated box and position via API.
07. Oct 2020 12:26:24 CEST jreher Assigned to capsule by script
17. Aug 2020 15:50:35 CEST jreher Updated box and position via API.
11. Aug 2020 17:49:13 CEST jreher Updated APD characteristics via API.
21. Jul 2020 14:33:47 CEST jreher Updated box and position via API.
20. Feb 2020 13:34:55 CET jreher Updated box and position via API.
27. Nov 2019 20:14:19 CET jreher Updated APD location via API.
25. Nov 2019 17:30:23 CET jreher Updated box and position via API.
25. Nov 2019 17:23:05 CET spankonin Updated APD batch assignment via API.
25. Nov 2019 17:07:34 CET spankonin Updated APD batch assignment via API.
23. Jun 2016 11:49:56 CEST Tobias Imported from Hamamatsu datasheet.