RUB » Physics » The Faculty » Chairs and Working Groups » EP1 » PANDA FEMC Production Database

Show Hamamatsu Avalanche Photo Diode 1911021077 - Archived data from Tue, 08. December 2020 17:09:34 CET


This is all the information about APD 1911021077. If it is wrong, edit the data.

Subdetector specification:  
Serial: 1911021077
Type: Hamamatsu Avalanche Photo Diode
Detector: assigned to 2308024790/1911021077
Unit: unassigned
Preamp: 0
Current location: Bochum
   
Installation information:  
Label: red
   
Manufacturer information:  
Wafer position: B09
Break-through voltage: 410 V
Voltage for Gain 100 (T=+25°C): 381.8 V
Dark current: 16.2 nA
   
Screening Logistics:  
Available: No
Storage Box: 239
Position in Box: 21
EP1 batch: none
EP1 batch after irradiation: none
   
Shipment:  
Grid number: none
Position in grid: none
Arrival for irradiation: none
Sent for analysis after irradiation: none
Return for assembly: none
   
Irradiation:  
Date: none
Dose used: none
Temperature: none
Position: none
Bias voltage: none     
   
Annealing:  
Date: none
Temperature: none
Duration: none
   
Measurement results:  
Voltage for Gain 100: T = +20 °C: 382.407185 V     T = -25 °C: 346.7311187 V
Voltage for Gain 150: T = +20 °C: 390.2380161 V     T = -25 °C: 354.1743185 V
Voltage for Gain 200: T = +20 °C: 394.5817513 V     T = -25 °C: 358.3786721 V
Gain/Voltage slope at M = 100: T = +20 °C: 4.45588138 V-1     T = -25 °C: 4.975800857 V-1
Gain/Voltage slope at M = 150: T = +20 °C: 8.759505123 V-1     T = -25 °C: 9.181201823 V-1
Gain/Voltage slope at M = 200: T = +20 °C: 15.24876785 V-1     T = -25 °C: 16.16998414 V-1
Break-through voltage: T = +20 °C: 407.7389154 V     T = -25 °C: 373.5614535 V
   
Notes:


Version history

Time Author Change comment
05. Feb 2021 11:19:07 CET jreher Updated box and position via API.
08. Dec 2020 17:09:34 CET jreher Assigned to capsule by script
06. Oct 2020 16:51:40 CEST jreher Updated box and position via API.
11. Aug 2020 17:47:33 CEST jreher Updated APD characteristics via API.
21. Jul 2020 14:30:50 CEST jreher Updated box and position via API.
27. Nov 2019 20:11:23 CET jreher Updated APD location via API.
25. Nov 2019 17:29:27 CET jreher Updated box and position via API.
18. Nov 2019 18:20:56 CET spankonin Updated APD location via API.
18. Nov 2019 18:13:31 CET spankonin Updated APD batch assignment via API.
23. Jun 2016 11:49:53 CEST Tobias Imported from Hamamatsu datasheet.