Subdetector specification:  
Serial: 1910021056
Type: Hamamatsu Avalanche Photo Diode
Detector: unassigned
Unit: unassigned
Preamp: 0
Current location: Bochum
   
Installation information:  
Label: none
   
Manufacturer information:  
Wafer position: G04
Break-through voltage: 407 V
Voltage for Gain 100 (T=+25°C): 378.7 V
Dark current: 12.4 nA
   
Screening Logistics:  
Available: Yes
Storage Box: 237
Position in Box: 20
EP1 batch: none
EP1 batch after irradiation: none
   
Shipment:  
Grid number: none
Position in grid: none
Arrival for irradiation: none
Sent for analysis after irradiation: none
Return for assembly: none
   
Irradiation:  
Date: none
Dose used: none
Temperature: none
Position: none
Bias voltage: none     
   
Annealing:  
Date: none
Temperature: none
Duration: none
   
Measurement results:  
Voltage for Gain 100: T = +20 °C: 379.2928045 V     T = -25 °C: 343.8217871 V
Voltage for Gain 150: T = +20 °C: 387.0788547 V     T = -25 °C: 351.1251883 V
Voltage for Gain 200: T = +20 °C: 391.4046064 V     T = -25 °C: 355.2409749 V
Gain/Voltage slope at M = 100: T = +20 °C: 4.548108628 V-1     T = -25 °C: 5.076130358 V-1
Gain/Voltage slope at M = 150: T = +20 °C: 9.052279258 V-1     T = -25 °C: 9.537913414 V-1
Gain/Voltage slope at M = 200: T = +20 °C: 14.18432959 V-1     T = -25 °C: 15.19168625 V-1
Break-through voltage: T = +20 °C: 406.8129294 V     T = -25 °C: 370.5080871 V
   
Notes:


Version history

Time Author Change comment
05. Feb 2021 11:18:51 CET jreher Updated box and position via API.
07. Oct 2020 12:28:11 CEST jreher Assigned to capsule by script
17. Aug 2020 15:53:39 CEST jreher Updated box and position via API.
11. Aug 2020 17:47:13 CEST jreher Updated APD characteristics via API.
21. Jul 2020 14:30:30 CEST jreher Updated box and position via API.
27. Nov 2019 20:11:01 CET jreher Updated APD location via API.
25. Nov 2019 17:29:17 CET jreher Updated box and position via API.
18. Nov 2019 18:20:05 CET spankonin Updated APD location via API.
18. Nov 2019 18:15:53 CET spankonin Updated APD batch assignment via API.
23. Jun 2016 11:49:03 CEST Tobias Imported from Hamamatsu datasheet.