RUB » Physics » The Faculty » Chairs and Working Groups » EP1 » PANDA FEMC Production Database

Show Hamamatsu Avalanche Photo Diode 1910021051 - Archived data from Thu, 15. April 2021 17:01:05 CEST


This is all the information about APD 1910021051. If it is wrong, edit the data.

Subdetector specification:  
Serial: 1910021051
Type: Hamamatsu Avalanche Photo Diode
Detector: unassigned
Unit: unassigned
Preamp: 0
Current location: Bochum
   
Installation information:  
Label: none
   
Manufacturer information:  
Wafer position: B10
Break-through voltage: 407 V
Voltage for Gain 100 (T=+25°C): 379.8 V
Dark current: 17 nA
   
Screening Logistics:  
Available: Yes
Storage Box: 237
Position in Box: 15
EP1 batch: none
EP1 batch after irradiation: none
   
Shipment:  
Grid number: none
Position in grid: none
Arrival for irradiation: none
Sent for analysis after irradiation: none
Return for assembly: none
   
Irradiation:  
Date: none
Dose used: none
Temperature: none
Position: none
Bias voltage: none     
   
Annealing:  
Date: none
Temperature: none
Duration: none
   
Measurement results:  
Voltage for Gain 100: T = +20 °C: 379.533742 V     T = -25 °C: 344.319499 V
Voltage for Gain 150: T = +20 °C: 387.3382045 V     T = -25 °C: 351.6868197 V
Voltage for Gain 200: T = +20 °C: 391.669769 V     T = -25 °C: 355.8203888 V
Gain/Voltage slope at M = 100: T = +20 °C: 4.436630827 V-1     T = -25 °C: 4.817552589 V-1
Gain/Voltage slope at M = 150: T = +20 °C: 8.732178274 V-1     T = -25 °C: 9.819275421 V-1
Gain/Voltage slope at M = 200: T = +20 °C: 15.20352034 V-1     T = -25 °C: 15.60404366 V-1
Break-through voltage: T = +20 °C: 404.6594339 V     T = -25 °C: 370.7748758 V
   
Notes:


Version history

Time Author Change comment
17. Jun 2021 19:46:17 CEST oafedulidis Assigned to capsule by script
15. Apr 2021 17:01:05 CEST jreher Updated box and position via API.
05. Feb 2021 11:18:50 CET jreher Updated box and position via API.
11. Aug 2020 17:47:12 CEST jreher Updated APD characteristics via API.
21. Jul 2020 14:30:29 CEST jreher Updated box and position via API.
27. Nov 2019 20:11:01 CET jreher Updated APD location via API.
25. Nov 2019 17:29:17 CET jreher Updated box and position via API.
18. Nov 2019 18:20:04 CET spankonin Updated APD location via API.
18. Nov 2019 18:16:20 CET spankonin Updated APD batch assignment via API.
23. Jun 2016 11:49:03 CEST Tobias Imported from Hamamatsu datasheet.