RUB » Physics » The Faculty » Chairs and Working Groups » EP1 » PANDA FEMC Production Database

Show Hamamatsu Avalanche Photo Diode 1910021025 - Archived data from Tue, 06. October 2020 16:51:53 CEST


This is all the information about APD 1910021025. If it is wrong, edit the data.

Subdetector specification:  
Serial: 1910021025
Type: Hamamatsu Avalanche Photo Diode
Detector: unassigned
Unit: unassigned
Preamp: 0
Current location: Bochum
   
Installation information:  
Label: none
   
Manufacturer information:  
Wafer position: E10
Break-through voltage: 407 V
Voltage for Gain 100 (T=+25°C): 378.3 V
Dark current: 15.8 nA
   
Screening Logistics:  
Available: Yes
Storage Box: 237
Position in Box: 30
EP1 batch: none
EP1 batch after irradiation: none
   
Shipment:  
Grid number: none
Position in grid: none
Arrival for irradiation: none
Sent for analysis after irradiation: none
Return for assembly: none
   
Irradiation:  
Date: none
Dose used: none
Temperature: none
Position: none
Bias voltage: none     
   
Annealing:  
Date: none
Temperature: none
Duration: none
   
Measurement results:  
Voltage for Gain 100: T = +20 °C: 378.4066325 V     T = -25 °C: 343.3343115 V
Voltage for Gain 150: T = +20 °C: 386.2692008 V     T = -25 °C: 350.6534244 V
Voltage for Gain 200: T = +20 °C: 390.6424187 V     T = -25 °C: 354.7493645 V
Gain/Voltage slope at M = 100: T = +20 °C: 4.472840182 V-1     T = -25 °C: 4.896425602 V-1
Gain/Voltage slope at M = 150: T = +20 °C: 8.796981824 V-1     T = -25 °C: 9.075129865 V-1
Gain/Voltage slope at M = 200: T = +20 °C: 15.49329524 V-1     T = -25 °C: 16.25423119 V-1
Break-through voltage: T = +20 °C: 405.8258138 V     T = -25 °C: 369.5639836 V
   
Notes:


Version history

Time Author Change comment
05. Feb 2021 11:18:52 CET jreher Updated box and position via API.
08. Dec 2020 17:10:58 CET jreher Assigned to capsule by script
06. Oct 2020 16:51:53 CEST jreher Updated box and position via API.
11. Aug 2020 17:47:15 CEST jreher Updated APD characteristics via API.
21. Jul 2020 14:30:31 CEST jreher Updated box and position via API.
27. Nov 2019 20:11:02 CET jreher Updated APD location via API.
25. Nov 2019 17:29:18 CET jreher Updated box and position via API.
18. Nov 2019 18:20:06 CET spankonin Updated APD location via API.
18. Nov 2019 18:15:54 CET spankonin Updated APD batch assignment via API.
23. Jun 2016 11:49:02 CEST Tobias Imported from Hamamatsu datasheet.