RUB » Physics » The Faculty » Chairs and Working Groups » EP1 » PANDA FEMC Production Database

Show Hamamatsu Avalanche Photo Diode 1909020967 - Archived data from Tue, 11. August 2020 18:09:09 CEST


This is all the information about APD 1909020967. If it is wrong, edit the data.

Subdetector specification:  
Serial: 1909020967
Type: Hamamatsu Avalanche Photo Diode
Detector: unassigned
Unit: unassigned
Preamp: 0
Current location: Bochum
   
Installation information:  
Label: none
   
Manufacturer information:  
Wafer position: F10
Break-through voltage: 413 V
Voltage for Gain 100 (T=+25°C): 385.5 V
Dark current: 18.3 nA
   
Screening Logistics:  
Available: Yes
Storage Box: 251
Position in Box: 10
EP1 batch: none
EP1 batch after irradiation: none
   
Shipment:  
Grid number: none
Position in grid: none
Arrival for irradiation: none
Sent for analysis after irradiation: none
Return for assembly: none
   
Irradiation:  
Date: none
Dose used: none
Temperature: none
Position: none
Bias voltage: none     
   
Annealing:  
Date: none
Temperature: none
Duration: none
   
Measurement results:  
Voltage for Gain 100: T = +20 °C: 385.5603922 V     T = -25 °C: 349.8564137 V
Voltage for Gain 150: T = +20 °C: 408.0086834 V     T = -25 °C: 357.3578316 V
Voltage for Gain 200: T = +20 °C: 409.4381723 V     T = -25 °C: 361.5704978 V
Gain/Voltage slope at M = 100: T = +20 °C: 4.424771549 V-1     T = -25 °C: 4.929172162 V-1
Gain/Voltage slope at M = 150: T = +20 °C: 24.81932095 V-1     T = -25 °C: 9.039120417 V-1
Gain/Voltage slope at M = 200: T = +20 °C: 41.70713729 V-1     T = -25 °C: 15.96716712 V-1
Break-through voltage: T = +20 °C: 408.3790931 V     T = -25 °C: 376.5217915 V
   
Notes:


Version history

Time Author Change comment
05. Feb 2021 11:20:35 CET jreher Updated box and position via API.
11. Aug 2020 18:09:09 CEST jreher Updated APD characteristics via API.
21. Jul 2020 14:32:48 CEST jreher Updated APD location via API.
21. Jul 2020 14:32:38 CEST jreher Updated box and position via API.
29. Jun 2020 16:10:18 CEST jreher Updated APD batch assignment via API.
23. Jun 2016 11:49:01 CEST Tobias Imported from Hamamatsu datasheet.