RUB » Physics » The Faculty » Chairs and Working Groups » EP1 » PANDA FEMC Production Database

Show Hamamatsu Avalanche Photo Diode 1909020956 - Archived data from Tue, 11. August 2020 18:09:15 CEST


This is all the information about APD 1909020956. If it is wrong, edit the data.

Subdetector specification:  
Serial: 1909020956
Type: Hamamatsu Avalanche Photo Diode
Detector: unassigned
Unit: unassigned
Preamp: 0
Current location: Bochum
   
Installation information:  
Label: none
   
Manufacturer information:  
Wafer position: F06
Break-through voltage: 409 V
Voltage for Gain 100 (T=+25°C): 380.7 V
Dark current: 9.3 nA
   
Screening Logistics:  
Available: Yes
Storage Box: 251
Position in Box: 40
EP1 batch: none
EP1 batch after irradiation: none
   
Shipment:  
Grid number: none
Position in grid: none
Arrival for irradiation: none
Sent for analysis after irradiation: none
Return for assembly: none
   
Irradiation:  
Date: none
Dose used: none
Temperature: none
Position: none
Bias voltage: none     
   
Annealing:  
Date: none
Temperature: none
Duration: none
   
Measurement results:  
Voltage for Gain 100: T = +20 °C: 389.8490702 V     T = -25 °C: 350.6361027 V
Voltage for Gain 150: T = +20 °C: 397.1336877 V     T = -25 °C: 358.4413206 V
Voltage for Gain 200: T = +20 °C: 401.1532844 V     T = -25 °C: 362.8183285 V
Gain/Voltage slope at M = 100: T = +20 °C: 4.976211565 V-1     T = -25 °C: 4.490853648 V-1
Gain/Voltage slope at M = 150: T = +20 °C: 9.513843 V-1     T = -25 °C: 8.598972156 V-1
Gain/Voltage slope at M = 200: T = +20 °C: 15.36350103 V-1     T = -25 °C: 14.72353647 V-1
Break-through voltage: T = +20 °C: 415.0698882 V     T = -25 °C: 379.0433836 V
   
Notes:


Version history

Time Author Change comment
05. Feb 2021 11:20:39 CET jreher Updated box and position via API.
11. Aug 2020 18:09:15 CEST jreher Updated APD characteristics via API.
21. Jul 2020 14:32:50 CEST jreher Updated APD location via API.
21. Jul 2020 14:32:40 CEST jreher Updated box and position via API.
09. Jul 2020 15:02:01 CEST jreher Updated APD batch assignment via API.
23. Jun 2016 11:49:01 CEST Tobias Imported from Hamamatsu datasheet.