RUB » Physics » The Faculty » Chairs and Working Groups » EP1 » PANDA FEMC Production Database

Show Hamamatsu Avalanche Photo Diode 0716006629 - Archived data from Fri, 05. February 2021 11:25:45 CET


This is all the information about APD 0716006629. If it is wrong, edit the data.

Subdetector specification:  
Serial: 0716006629
Type: Hamamatsu Avalanche Photo Diode
Detector: unassigned
Unit: unassigned
Preamp: 0
Current location: Bochum
   
Installation information:  
Label: none
   
Manufacturer information:  
Wafer position: F05
Break-through voltage: 405 V
Voltage for Gain 100 (T=+25°C): 376.7 V
Dark current: 13.7 nA
   
Screening Logistics:  
Available: Yes
Storage Box: 290
Position in Box: 41
EP1 batch: none
EP1 batch after irradiation: none
   
Shipment:  
Grid number: 55
Position in grid: 9
Arrival for irradiation: 10. Jul 2016
Sent for analysis after irradiation: 22. Jul 2016
Return for assembly: 06. Oct 2016
   
Irradiation:  
Date: 12. Jul 2016
Dose used: 30 Gy
Temperature: 25 °C
Position: 3
Bias voltage: 320 V     (connection unknown)
   
Annealing:  
Date: 12. Jul 2016
Temperature: 80 °C
Duration: 10 h
   
Measurement results:  
Voltage for Gain 100: T = +20 °C: 376.7854575 V     T = -25 °C: 341.7502619 V
Voltage for Gain 150: T = +20 °C: 384.5750664 V     T = -25 °C: 349.0118747 V
Voltage for Gain 200: T = +20 °C: 388.9023885 V     T = -25 °C: 353.0999752 V
Gain/Voltage slope at M = 100: T = +20 °C: 4.741950953 V-1     T = -25 °C: 5.13534081 V-1
Gain/Voltage slope at M = 150: T = +20 °C: 8.557043696 V-1     T = -25 °C: 9.640790137 V-1
Gain/Voltage slope at M = 200: T = +20 °C: 14.9225505 V-1     T = -25 °C: 15.401739 V-1
Break-through voltage: T = +20 °C: 404.7096291 V     T = -25 °C: 368.4662904 V
   
Notes:


Version history

Time Author Change comment
26. Oct 2021 15:17:17 CEST oafedulidis Assigned to capsule by script
10. May 2021 14:01:55 CEST oafedulidis Updated box and position via API.
05. Feb 2021 11:25:45 CET jreher Updated box and position via API.
11. Aug 2020 17:40:25 CEST jreher Updated APD characteristics via API.
21. Jul 2020 14:40:42 CEST jreher Updated box and position via API.
27. Nov 2019 20:18:51 CET jreher Updated APD location via API.
25. Nov 2019 17:31:29 CET jreher Updated box and position via API.
22. Oct 2019 14:32:01 CEST spankonin Updated APD location via API.
15. Oct 2019 11:02:53 CEST jgrochowski Updated APD batch assignment via API.
06. Oct 2016 09:44:47 CEST markus.moritz Entered return for assembly date.
03. Aug 2016 16:02:46 CEST markus.moritz Entered shipped after irradiation date.
03. Aug 2016 16:02:31 CEST markus.moritz Entered arrival for irradiation date.
02. Aug 2016 14:57:36 CEST christopher.l.hahn Entered annealing information.
02. Aug 2016 13:59:15 CEST markus.moritz Entered irradiation information.
01. Aug 2016 17:27:48 CEST Tobias Assigned to grid via information extracted from APD DB.
22. Jun 2016 15:13:16 CEST Tobias Imported from Hamamatsu datasheet.