Show Hamamatsu Avalanche Photo Diode 0716006629


This is all the information about APD 0716006629. If it is wrong, edit the data.

Subdetector specification:  
Serial: 0716006629
Type: Hamamatsu Avalanche Photo Diode
Detector: assigned to 0716006629/3104034086
Unit: #2696 (barcode 1309029839)
Preamp: 0
Current location: Bochum
   
Installation information:  
Label: blue
   
Manufacturer information:  
Wafer position: F05
Break-through voltage: 405 V
Voltage for Gain 100 (T=+25°C): 376.7 V
Dark current: 13.7 nA
   
Screening Logistics:  
Available: No
Storage Box: 290
Position in Box: 41
EP1 batch: none
EP1 batch after irradiation: 10203
   
Shipment:  
Grid number: 55
Position in grid: 9
Arrival for irradiation: 10. Jul 2016
Sent for analysis after irradiation: 22. Jul 2016
Return for assembly: 06. Oct 2016
   
Irradiation:  
Date: 12. Jul 2016
Dose used: 30 Gy
Temperature: 25 °C
Position: 3
Bias voltage: 320 V     (connection unknown)
   
Annealing:  
Date: 12. Jul 2016
Temperature: 80 °C
Duration: 10 h
   
Measurement results:  
Voltage for Gain 100: T = +20 °C: 376.7854575 V     T = -25 °C: 341.7502619 V
Voltage for Gain 150: T = +20 °C: 384.5750664 V     T = -25 °C: 349.0118747 V
Voltage for Gain 200: T = +20 °C: 388.9023885 V     T = -25 °C: 353.0999752 V
Gain/Voltage slope at M = 100: T = +20 °C: 4.741950953 V-1     T = -25 °C: 5.13534081 V-1
Gain/Voltage slope at M = 150: T = +20 °C: 8.557043696 V-1     T = -25 °C: 9.640790137 V-1
Gain/Voltage slope at M = 200: T = +20 °C: 14.9225505 V-1     T = -25 °C: 15.401739 V-1
Break-through voltage: T = +20 °C: 404.7096291 V     T = -25 °C: 368.4662904 V
   
Notes:


Characteristics

Temperature Measurement Notes
No characteristics available!


Upload new characteristic...

Progression of the current during irradiation

Upload time Notes
No data available!


Upload new progression data...

Version history

Time Author Change comment
26. Oct 2021 15:17:17 CEST oafedulidis Assigned to capsule by script
10. May 2021 14:01:55 CEST oafedulidis Updated box and position via API.
05. Feb 2021 11:25:45 CET jreher Updated box and position via API.
11. Aug 2020 17:40:25 CEST jreher Updated APD characteristics via API.
21. Jul 2020 14:40:42 CEST jreher Updated box and position via API.
27. Nov 2019 20:18:51 CET jreher Updated APD location via API.
25. Nov 2019 17:31:29 CET jreher Updated box and position via API.
22. Oct 2019 14:32:01 CEST spankonin Updated APD location via API.
15. Oct 2019 11:02:53 CEST jgrochowski Updated APD batch assignment via API.
06. Oct 2016 09:44:47 CEST markus.moritz Entered return for assembly date.
03. Aug 2016 16:02:46 CEST markus.moritz Entered shipped after irradiation date.
03. Aug 2016 16:02:31 CEST markus.moritz Entered arrival for irradiation date.
02. Aug 2016 14:57:36 CEST christopher.l.hahn Entered annealing information.
02. Aug 2016 13:59:15 CEST markus.moritz Entered irradiation information.
01. Aug 2016 17:27:48 CEST Tobias Assigned to grid via information extracted from APD DB.
22. Jun 2016 15:13:16 CEST Tobias Imported from Hamamatsu datasheet.