RUB » Physics » The Faculty » Chairs and Working Groups » EP1 » PANDA FEMC Production Database

Show Hamamatsu Avalanche Photo Diode 1908020841 - Archived data from Tue, 11. August 2020 17:52:33 CEST


This is all the information about APD 1908020841. If it is wrong, edit the data.

Subdetector specification:  
Serial: 1908020841
Type: Hamamatsu Avalanche Photo Diode
Detector: unassigned
Unit: unassigned
Preamp: 0
Current location: Bochum
   
Installation information:  
Label: none
   
Manufacturer information:  
Wafer position: D01
Break-through voltage: 399 V
Voltage for Gain 100 (T=+25°C): 371 V
Dark current: 12.7 nA
   
Screening Logistics:  
Available: Yes
Storage Box: 280
Position in Box: 15
EP1 batch: none
EP1 batch after irradiation: none
   
Shipment:  
Grid number: none
Position in grid: none
Arrival for irradiation: none
Sent for analysis after irradiation: none
Return for assembly: none
   
Irradiation:  
Date: none
Dose used: none
Temperature: none
Position: none
Bias voltage: none     
   
Annealing:  
Date: none
Temperature: none
Duration: none
   
Measurement results:  
Voltage for Gain 100: T = +20 °C: 373.8330194 V     T = -25 °C: 336.9396185 V
Voltage for Gain 150: T = +20 °C: 381.2383042 V     T = -25 °C: 344.2560063 V
Voltage for Gain 200: T = +20 °C: 385.3577928 V     T = -25 °C: 348.398293 V
Gain/Voltage slope at M = 100: T = +20 °C: 4.95036485 V-1     T = -25 °C: 5.057982292 V-1
Gain/Voltage slope at M = 150: T = +20 °C: 9.26495626 V-1     T = -25 °C: 9.287475913 V-1
Gain/Voltage slope at M = 200: T = +20 °C: 14.7244169 V-1     T = -25 °C: 14.58065417 V-1
Break-through voltage: T = +20 °C: 398.5976385 V     T = -25 °C: 362.7310354 V
   
Notes:


Version history

Time Author Change comment
05. Feb 2021 11:24:26 CET jreher Updated box and position via API.
11. Aug 2020 17:52:33 CEST jreher Updated APD characteristics via API.
21. Jul 2020 14:38:40 CEST jreher Updated APD location via API.
21. Jul 2020 14:38:29 CEST jreher Updated box and position via API.
12. Dec 2019 12:01:28 CET jreher Updated box and position via API.
09. Dec 2019 18:28:40 CET spankonin Updated box and position via API.
05. Dec 2019 17:39:14 CET spankonin Updated APD batch assignment via API.
23. Jun 2016 11:48:58 CEST Tobias Imported from Hamamatsu datasheet.