RUB » Physics » The Faculty » Chairs and Working Groups » EP1 » PANDA FEMC Production Database

Show Hamamatsu Avalanche Photo Diode 1907020813 - Archived data from Tue, 11. August 2020 17:52:37 CEST


This is all the information about APD 1907020813. If it is wrong, edit the data.

Subdetector specification:  
Serial: 1907020813
Type: Hamamatsu Avalanche Photo Diode
Detector: unassigned
Unit: unassigned
Preamp: 0
Current location: Bochum
   
Installation information:  
Label: none
   
Manufacturer information:  
Wafer position: D14
Break-through voltage: 407 V
Voltage for Gain 100 (T=+25°C): 379.1 V
Dark current: 22.2 nA
   
Screening Logistics:  
Available: Yes
Storage Box: 280
Position in Box: 34
EP1 batch: none
EP1 batch after irradiation: none
   
Shipment:  
Grid number: none
Position in grid: none
Arrival for irradiation: none
Sent for analysis after irradiation: none
Return for assembly: none
   
Irradiation:  
Date: none
Dose used: none
Temperature: none
Position: none
Bias voltage: none     
   
Annealing:  
Date: none
Temperature: none
Duration: none
   
Measurement results:  
Voltage for Gain 100: T = +20 °C: 379.3857941 V     T = -25 °C: 343.8303733 V
Voltage for Gain 150: T = +20 °C: 387.1853228 V     T = -25 °C: 351.1755236 V
Voltage for Gain 200: T = +20 °C: 391.5314235 V     T = -25 °C: 355.3109065 V
Gain/Voltage slope at M = 100: T = +20 °C: 4.514013038 V-1     T = -25 °C: 5.038938626 V-1
Gain/Voltage slope at M = 150: T = +20 °C: 8.851977543 V-1     T = -25 °C: 9.362593802 V-1
Gain/Voltage slope at M = 200: T = +20 °C: 15.53939535 V-1     T = -25 °C: 14.72700729 V-1
Break-through voltage: T = +20 °C: 406.2938154 V     T = -25 °C: 369.9646328 V
   
Notes:


Version history

Time Author Change comment
05. Feb 2021 11:24:28 CET jreher Updated box and position via API.
11. Aug 2020 17:52:37 CEST jreher Updated APD characteristics via API.
21. Jul 2020 14:38:41 CEST jreher Updated APD location via API.
21. Jul 2020 14:38:31 CEST jreher Updated box and position via API.
12. Dec 2019 12:01:29 CET jreher Updated box and position via API.
09. Dec 2019 18:28:42 CET spankonin Updated box and position via API.
09. Dec 2019 18:27:13 CET spankonin Updated APD batch assignment via API.
23. Jun 2016 11:48:57 CEST Tobias Imported from Hamamatsu datasheet.