Subdetector specification:  
Serial: 1907020768
Type: Hamamatsu Avalanche Photo Diode
Detector: unassigned
Unit: unassigned
Preamp: 0
Current location: Bochum
   
Installation information:  
Label: none
   
Manufacturer information:  
Wafer position: D06
Break-through voltage: 402 V
Voltage for Gain 100 (T=+25°C): 372.9 V
Dark current: 15.8 nA
   
Screening Logistics:  
Available: Yes
Storage Box: 277
Position in Box: 32
EP1 batch: none
EP1 batch after irradiation: none
   
Shipment:  
Grid number: none
Position in grid: none
Arrival for irradiation: none
Sent for analysis after irradiation: none
Return for assembly: none
   
Irradiation:  
Date: none
Dose used: none
Temperature: none
Position: none
Bias voltage: none     
   
Annealing:  
Date: none
Temperature: none
Duration: none
   
Measurement results:  
Voltage for Gain 100: T = +20 °C: 373.6326616 V     T = -25 °C: 338.7368837 V
Voltage for Gain 150: T = +20 °C: 381.4150983 V     T = -25 °C: 345.9222027 V
Voltage for Gain 200: T = +20 °C: 385.7630215 V     T = -25 °C: 349.9747582 V
Gain/Voltage slope at M = 100: T = +20 °C: 4.467281169 V-1     T = -25 °C: 5.163181903 V-1
Gain/Voltage slope at M = 150: T = +20 °C: 8.524515004 V-1     T = -25 °C: 9.751396219 V-1
Gain/Voltage slope at M = 200: T = +20 °C: 15.0420402 V-1     T = -25 °C: 15.50829688 V-1
Break-through voltage: T = +20 °C: 401.4985585 V     T = -25 °C: 365.1765615 V
   
Notes:


Version history

Time Author Change comment
05. Feb 2021 11:24:04 CET jreher Updated box and position via API.
11. Aug 2020 17:52:04 CEST jreher Updated APD characteristics via API.
21. Jul 2020 14:37:55 CEST jreher Updated APD location via API.
21. Jul 2020 14:37:45 CEST jreher Updated box and position via API.
12. Dec 2019 12:43:06 CET spankonin Updated box and position via API.
05. Dec 2019 18:00:43 CET spankonin Updated APD batch assignment via API.
23. Jun 2016 11:48:56 CEST Tobias Imported from Hamamatsu datasheet.