RUB » Physics » The Faculty » Chairs and Working Groups » EP1 » PANDA FEMC Production Database

Show Hamamatsu Avalanche Photo Diode 1906020751 - Archived data from Tue, 11. August 2020 17:35:27 CEST


This is all the information about APD 1906020751. If it is wrong, edit the data.

Subdetector specification:  
Serial: 1906020751
Type: Hamamatsu Avalanche Photo Diode
Detector: unassigned
Unit: unassigned
Preamp: 0
Current location: Bochum
   
Installation information:  
Label: none
   
Manufacturer information:  
Wafer position: C03
Break-through voltage: 404 V
Voltage for Gain 100 (T=+25°C): 376 V
Dark current: 17.4 nA
   
Screening Logistics:  
Available: Yes
Storage Box: 194
Position in Box: 4
EP1 batch: none
EP1 batch after irradiation: none
   
Shipment:  
Grid number: none
Position in grid: none
Arrival for irradiation: 18. Apr 2019
Sent for analysis after irradiation: 29. Jul 2019
Return for assembly: none
   
Irradiation:  
Date: 25. Jul 2019
Dose used: 37 Gy
Temperature: 20 °C
Position: none
Bias voltage: none     
   
Annealing:  
Date: 27. Jul 2019
Temperature: 80 °C
Duration: 48 h
   
Measurement results:  
Voltage for Gain 100: T = +20 °C: 376.7172175 V     T = -25 °C: 341.3552149 V
Voltage for Gain 150: T = +20 °C: 384.5061202 V     T = -25 °C: 348.6391804 V
Voltage for Gain 200: T = +20 °C: 388.8194888 V     T = -25 °C: 352.7257072 V
Gain/Voltage slope at M = 100: T = +20 °C: 4.758076999 V-1     T = -25 °C: 4.851835817 V-1
Gain/Voltage slope at M = 150: T = +20 °C: 8.554938821 V-1     T = -25 °C: 9.968462269 V-1
Gain/Voltage slope at M = 200: T = +20 °C: 14.92372823 V-1     T = -25 °C: 16.00914146 V-1
Break-through voltage: T = +20 °C: 403.3087129 V     T = -25 °C: 366.9520304 V
   
Notes:


Version history

Time Author Change comment
26. Oct 2021 10:09:41 CEST oafedulidis Assigned to capsule by script
15. Apr 2021 17:01:28 CEST jreher Updated box and position via API.
05. Feb 2021 11:13:21 CET jreher Updated box and position via API.
11. Aug 2020 17:35:27 CEST jreher Updated APD characteristics via API.
27. Nov 2019 20:03:22 CET jreher Updated APD location via API.
25. Nov 2019 17:26:08 CET jreher Updated box and position via API.
16. Aug 2019 12:20:56 CEST jreher Updated APD location via API.
09. Aug 2019 16:47:35 CEST jreher Updated APD batch assignment via API.
09. Aug 2019 16:41:27 CEST jreher Updated APD batch assignment via API.
09. Aug 2019 16:35:28 CEST jreher Updated APD batch assignment via API.
31. Jul 2019 13:27:25 CEST markus.moritz
23. Jun 2016 11:48:56 CEST Tobias Imported from Hamamatsu datasheet.