RUB » Physics » The Faculty » Chairs and Working Groups » EP1 » PANDA FEMC Production Database

Show Hamamatsu Avalanche Photo Diode 1906020694 - Archived data from Tue, 11. August 2020 17:35:19 CEST


This is all the information about APD 1906020694. If it is wrong, edit the data.

Subdetector specification:  
Serial: 1906020694
Type: Hamamatsu Avalanche Photo Diode
Detector: unassigned
Unit: unassigned
Preamp: 0
Current location: Bochum
   
Installation information:  
Label: none
   
Manufacturer information:  
Wafer position: F06
Break-through voltage: 403 V
Voltage for Gain 100 (T=+25°C): 374.8 V
Dark current: 8.2 nA
   
Screening Logistics:  
Available: Yes
Storage Box: 193
Position in Box: 16
EP1 batch: none
EP1 batch after irradiation: none
   
Shipment:  
Grid number: none
Position in grid: none
Arrival for irradiation: 18. Apr 2019
Sent for analysis after irradiation: 29. Jul 2019
Return for assembly: none
   
Irradiation:  
Date: 25. Jul 2019
Dose used: 37 Gy
Temperature: 20 °C
Position: none
Bias voltage: none     
   
Annealing:  
Date: 27. Jul 2019
Temperature: 80 °C
Duration: 48 h
   
Measurement results:  
Voltage for Gain 100: T = +20 °C: 375.2592278 V     T = -25 °C: 340.0700263 V
Voltage for Gain 150: T = +20 °C: 383.0214591 V     T = -25 °C: 347.3281736 V
Voltage for Gain 200: T = +20 °C: 387.3508542 V     T = -25 °C: 351.4203261 V
Gain/Voltage slope at M = 100: T = +20 °C: 4.548012902 V-1     T = -25 °C: 4.957879532 V-1
Gain/Voltage slope at M = 150: T = +20 °C: 8.985422457 V-1     T = -25 °C: 9.249916982 V-1
Gain/Voltage slope at M = 200: T = +20 °C: 15.75774413 V-1     T = -25 °C: 16.47469197 V-1
Break-through voltage: T = +20 °C: 402.8213777 V     T = -25 °C: 366.3668355 V
   
Notes:


Version history

Time Author Change comment
07. Feb 2022 10:46:37 CET oafedulidis Assigned to capsule by script
16. Jun 2021 16:04:25 CEST oafedulidis Updated box and position via API.
16. Jun 2021 16:00:38 CEST oafedulidis Updated box and position via API.
16. Jun 2021 15:53:19 CEST oafedulidis Updated box and position via API.
05. Feb 2021 11:13:14 CET jreher Updated box and position via API.
11. Aug 2020 17:35:19 CEST jreher Updated APD characteristics via API.
27. Nov 2019 20:03:12 CET jreher Updated APD location via API.
25. Nov 2019 17:26:04 CET jreher Updated box and position via API.
16. Aug 2019 12:20:46 CEST jreher Updated APD location via API.
09. Aug 2019 16:30:44 CEST jreher Updated APD batch assignment via API.
31. Jul 2019 13:32:49 CEST markus.moritz
23. Jun 2016 11:48:54 CEST Tobias Imported from Hamamatsu datasheet.