Serial: 1905020650
Type: Hamamatsu Avalanche Photo Diode
Detector: assigned to 2520029115/1905020650
Unit: unassigned
Preamp: 0
Current location: Bochum
   
Installation information:  
Label: red
   
Manufacturer information:  
Wafer position: D12
Break-through voltage: 408 V
Voltage for Gain 100 (T=+25°C): 379.9 V
Dark current: 11.3 nA
   
Screening Logistics:  
Available: No
Storage Box: 188
Position in Box: 25
EP1 batch: none
EP1 batch after irradiation: none
   
Shipment:  
Grid number: none
Position in grid: none
Arrival for irradiation: 18. Apr 2019
Sent for analysis after irradiation: 29. Jul 2019
Return for assembly: none
   
Irradiation:  
Date: 25. Jul 2019
Dose used: 37 Gy
Temperature: 20 °C
Position: none
Bias voltage: none     
   
Annealing:  
Date: 27. Jul 2019
Temperature: 80 °C
Duration: 48 h
   
Measurement results:  
Voltage for Gain 100: T = +20 °C: 380.8051535 V     T = -25 °C: 345.0969568 V
Voltage for Gain 150: T = +20 °C: 388.5509936 V     T = -25 °C: 352.4910853 V
Voltage for Gain 200: T = +20 °C: 392.8393508 V     T = -25 °C: 356.6468009 V
Gain/Voltage slope at M = 100: T = +20 °C: 4.749979543 V-1     T = -25 °C: 4.915023705 V-1
Gain/Voltage slope at M = 150: T = +20 °C: 8.690352527 V-1     T = -25 °C: 9.075761637 V-1
Gain/Voltage slope at M = 200: T = +20 °C: 15.29789464 V-1     T = -25 °C: 16.22304536 V-1
Break-through voltage: T = +20 °C: 407.9652111 V     T = -25 °C: 371.7086643 V
   
Notes:


Version history

Time Author Change comment
05. Feb 2021 11:12:35 CET jreher Updated box and position via API.
11. Aug 2020 17:34:30 CEST jreher Updated APD characteristics via API.
25. Jun 2020 11:21:59 CEST jreher Assigned to capsule by script
19. Feb 2020 11:53:41 CET jreher Updated box and position via API.
27. Nov 2019 20:02:18 CET jreher Updated APD location via API.
25. Nov 2019 17:25:41 CET jreher Updated box and position via API.
13. Aug 2019 12:17:12 CEST jreher Updated APD location via API.
05. Aug 2019 17:05:17 CEST jreher Updated APD batch assignment via API.
30. Jul 2019 13:04:19 CEST markus.moritz
23. Jun 2016 11:48:53 CEST Tobias Imported from Hamamatsu datasheet.