RUB » Physics » The Faculty » Chairs and Working Groups » EP1 » PANDA FEMC Production Database

Show Hamamatsu Avalanche Photo Diode 1905020614 - Archived data from Tue, 11. August 2020 18:09:55 CEST


This is all the information about APD 1905020614. If it is wrong, edit the data.

Subdetector specification:  
Serial: 1905020614
Type: Hamamatsu Avalanche Photo Diode
Detector: unassigned
Unit: unassigned
Preamp: 0
Current location: Bochum
   
Installation information:  
Label: none
   
Manufacturer information:  
Wafer position: C09
Break-through voltage: 403 V
Voltage for Gain 100 (T=+25°C): 375.4 V
Dark current: 10.5 nA
   
Screening Logistics:  
Available: Yes
Storage Box: 269
Position in Box: 12
EP1 batch: none
EP1 batch after irradiation: none
   
Shipment:  
Grid number: none
Position in grid: none
Arrival for irradiation: none
Sent for analysis after irradiation: none
Return for assembly: none
   
Irradiation:  
Date: none
Dose used: none
Temperature: none
Position: none
Bias voltage: none     
   
Annealing:  
Date: none
Temperature: none
Duration: none
   
Measurement results:  
Voltage for Gain 100: T = +20 °C: 387.718486 V     T = -25 °C: 340.6138168 V
Voltage for Gain 150: T = +20 °C: 392.6900578 V     T = -25 °C: 348.0929219 V
Voltage for Gain 200: T = +20 °C: 395.3434446 V     T = -25 °C: 352.3280222 V
Gain/Voltage slope at M = 100: T = +20 °C: 7.235309439 V-1     T = -25 °C: 4.696496549 V-1
Gain/Voltage slope at M = 150: T = +20 °C: 14.60261598 V-1     T = -25 °C: 9.280083347 V-1
Gain/Voltage slope at M = 200: T = +20 °C: 25.34295686 V-1     T = -25 °C: 14.50145583 V-1
Break-through voltage: T = +20 °C: 402.8683799 V     T = -25 °C: 366.8847748 V
   
Notes:


Version history

Time Author Change comment
05. Feb 2021 11:22:59 CET jreher Updated box and position via API.
11. Aug 2020 18:09:55 CEST jreher Updated APD characteristics via API.
21. Jul 2020 14:36:07 CEST jreher Updated APD location via API.
21. Jul 2020 14:35:57 CEST jreher Updated box and position via API.
29. Jun 2020 16:12:23 CEST jreher Updated APD batch assignment via API.
23. Jun 2016 11:48:52 CEST Tobias Imported from Hamamatsu datasheet.