Wafer position: F09
Break-through voltage: 404 V
Voltage for Gain 100 (T=+25°C): 376.2 V
Dark current: 11.1 nA
   
Screening Logistics:  
Available: Yes
Storage Box: 269
Position in Box: 11
EP1 batch: none
EP1 batch after irradiation: none
   
Shipment:  
Grid number: none
Position in grid: none
Arrival for irradiation: none
Sent for analysis after irradiation: none
Return for assembly: none
   
Irradiation:  
Date: none
Dose used: none
Temperature: none
Position: none
Bias voltage: none     
   
Annealing:  
Date: none
Temperature: none
Duration: none
   
Measurement results:  
Voltage for Gain 100: T = +20 °C: 384.3972932 V     T = -25 °C: 340.5657017 V
Voltage for Gain 150: T = +20 °C: 390.2601295 V     T = -25 °C: 348.0414285 V
Voltage for Gain 200: T = +20 °C: 393.4147144 V     T = -25 °C: 352.2771214 V
Gain/Voltage slope at M = 100: T = +20 °C: 5.785125862 V-1     T = -25 °C: 4.698583135 V-1
Gain/Voltage slope at M = 150: T = +20 °C: 11.45492314 V-1     T = -25 °C: 9.316653306 V-1
Gain/Voltage slope at M = 200: T = +20 °C: 21.15812747 V-1     T = -25 °C: 14.44576751 V-1
Break-through voltage: T = +20 °C: 403.1830556 V     T = -25 °C: 367.2550347 V
   
Notes:


Version history

Time Author Change comment
05. Feb 2021 11:22:58 CET jreher Updated box and position via API.
11. Aug 2020 18:09:55 CEST jreher Updated APD characteristics via API.
21. Jul 2020 14:36:07 CEST jreher Updated APD location via API.
21. Jul 2020 14:35:57 CEST jreher Updated box and position via API.
29. Jun 2020 16:12:23 CEST jreher Updated APD batch assignment via API.
23. Jun 2016 11:48:52 CEST Tobias Imported from Hamamatsu datasheet.