RUB » Physics » The Faculty » Chairs and Working Groups » EP1 » PANDA FEMC Production Database

Show Hamamatsu Avalanche Photo Diode 1903020515 - Archived data from Tue, 11. August 2020 18:08:29 CEST


This is all the information about APD 1903020515. If it is wrong, edit the data.

Subdetector specification:  
Serial: 1903020515
Type: Hamamatsu Avalanche Photo Diode
Detector: unassigned
Unit: unassigned
Preamp: 0
Current location: Bochum
   
Installation information:  
Label: none
   
Manufacturer information:  
Wafer position: H08
Break-through voltage: 403 V
Voltage for Gain 100 (T=+25°C): 374.7 V
Dark current: 17 nA
   
Screening Logistics:  
Available: Yes
Storage Box: 318
Position in Box: 14
EP1 batch: none
EP1 batch after irradiation: none
   
Shipment:  
Grid number: none
Position in grid: none
Arrival for irradiation: none
Sent for analysis after irradiation: none
Return for assembly: none
   
Irradiation:  
Date: none
Dose used: none
Temperature: none
Position: none
Bias voltage: none     
   
Annealing:  
Date: none
Temperature: none
Duration: none
   
Measurement results:  
Voltage for Gain 100: T = +20 °C: 328.6307903 V     T = -25 °C: 359.2980923 V
Voltage for Gain 150: T = +20 °C: 330.8198595 V     T = -25 °C: 361.7949837 V
Voltage for Gain 200: T = +20 °C: 344.943613 V     T = -25 °C: 363.2292538 V
Gain/Voltage slope at M = 100: T = +20 °C: 128.2592867 V-1     T = -25 °C: 15.05080636 V-1
Gain/Voltage slope at M = 150: T = +20 °C: 154.5835579 V-1     T = -25 °C: 25.73669099 V-1
Gain/Voltage slope at M = 200: T = +20 °C: 32.59467721 V-1     T = -25 °C: 50.70495087 V-1
Break-through voltage: T = +20 °C: 398.6096576 V     T = -25 °C: 366.5498129 V
   
Notes:


Version history

Time Author Change comment
05. Feb 2021 11:29:07 CET jreher Updated box and position via API.
11. Aug 2020 18:08:29 CEST jreher Updated APD characteristics via API.
21. Jul 2020 14:45:49 CEST jreher Updated APD location via API.
21. Jul 2020 14:45:39 CEST jreher Updated box and position via API.
29. Jun 2020 15:58:28 CEST jreher Updated APD batch assignment via API.
23. Jun 2016 11:48:50 CEST Tobias Imported from Hamamatsu datasheet.