RUB » Physics » The Faculty » Chairs and Working Groups » EP1 » PANDA FEMC Production Database

Show Hamamatsu Avalanche Photo Diode 1902020425 - Archived data from Tue, 11. August 2020 18:09:42 CEST


This is all the information about APD 1902020425. If it is wrong, edit the data.

Subdetector specification:  
Serial: 1902020425
Type: Hamamatsu Avalanche Photo Diode
Detector: unassigned
Unit: unassigned
Preamp: 0
Current location: Bochum
   
Installation information:  
Label: none
   
Manufacturer information:  
Wafer position: C14
Break-through voltage: 401 V
Voltage for Gain 100 (T=+25°C): 373.6 V
Dark current: 7.9 nA
   
Screening Logistics:  
Available: Yes
Storage Box: 209
Position in Box: 43
EP1 batch: none
EP1 batch after irradiation: none
   
Shipment:  
Grid number: none
Position in grid: none
Arrival for irradiation: none
Sent for analysis after irradiation: none
Return for assembly: none
   
Irradiation:  
Date: none
Dose used: none
Temperature: none
Position: none
Bias voltage: none     
   
Annealing:  
Date: none
Temperature: none
Duration: none
   
Measurement results:  
Voltage for Gain 100: T = +20 °C: 373.6079977 V     T = -25 °C: 338.8237132 V
Voltage for Gain 150: T = +20 °C: 381.3942962 V     T = -25 °C: 346.0141108 V
Voltage for Gain 200: T = +20 °C: 385.7275846 V     T = -25 °C: 350.0650203 V
Gain/Voltage slope at M = 100: T = +20 °C: 4.445608965 V-1     T = -25 °C: 5.11588737 V-1
Gain/Voltage slope at M = 150: T = +20 °C: 8.660936754 V-1     T = -25 °C: 9.606255717 V-1
Gain/Voltage slope at M = 200: T = +20 °C: 14.90138077 V-1     T = -25 °C: 15.32212273 V-1
Break-through voltage: T = +20 °C: 400.4993279 V     T = -25 °C: 364.6408789 V
   
Notes:


Version history

Time Author Change comment
05. Feb 2021 11:15:17 CET jreher Updated box and position via API.
11. Aug 2020 18:09:42 CEST jreher Updated APD characteristics via API.
21. Jul 2020 14:25:53 CEST jreher Updated APD location via API.
21. Jul 2020 14:25:44 CEST jreher Updated box and position via API.
29. Jun 2020 16:11:41 CEST jreher Updated APD batch assignment via API.
23. Jun 2016 11:48:48 CEST Tobias Imported from Hamamatsu datasheet.