RUB » Physics » The Faculty » Chairs and Working Groups » EP1 » PANDA FEMC Production Database

Show Hamamatsu Avalanche Photo Diode 1901020395 - Archived data from Tue, 11. August 2020 18:09:36 CEST


This is all the information about APD 1901020395. If it is wrong, edit the data.

Subdetector specification:  
Serial: 1901020395
Type: Hamamatsu Avalanche Photo Diode
Detector: unassigned
Unit: unassigned
Preamp: 0
Current location: Bochum
   
Installation information:  
Label: none
   
Manufacturer information:  
Wafer position: A07
Break-through voltage: 405 V
Voltage for Gain 100 (T=+25°C): 377.9 V
Dark current: 17.1 nA
   
Screening Logistics:  
Available: Yes
Storage Box: 209
Position in Box: 15
EP1 batch: none
EP1 batch after irradiation: none
   
Shipment:  
Grid number: none
Position in grid: none
Arrival for irradiation: none
Sent for analysis after irradiation: none
Return for assembly: none
   
Irradiation:  
Date: none
Dose used: none
Temperature: none
Position: none
Bias voltage: none     
   
Annealing:  
Date: none
Temperature: none
Duration: none
   
Measurement results:  
Voltage for Gain 100: T = +20 °C: 378.4418084 V     T = -25 °C: 342.7154501 V
Voltage for Gain 150: T = +20 °C: 386.2574137 V     T = -25 °C: 350.1012992 V
Voltage for Gain 200: T = +20 °C: 390.6016788 V     T = -25 °C: 354.2712665 V
Gain/Voltage slope at M = 100: T = +20 °C: 4.489790565 V-1     T = -25 °C: 5.05811371 V-1
Gain/Voltage slope at M = 150: T = +20 °C: 8.698171553 V-1     T = -25 °C: 9.309902658 V-1
Gain/Voltage slope at M = 200: T = +20 °C: 15.18147012 V-1     T = -25 °C: 14.72640198 V-1
Break-through voltage: T = +20 °C: 405.1345548 V     T = -25 °C: 368.6491274 V
   
Notes:


Version history

Time Author Change comment
05. Feb 2021 11:15:14 CET jreher Updated box and position via API.
11. Aug 2020 18:09:36 CEST jreher Updated APD characteristics via API.
21. Jul 2020 14:25:51 CEST jreher Updated APD location via API.
21. Jul 2020 14:25:41 CEST jreher Updated box and position via API.
29. Jun 2020 16:11:15 CEST jreher Updated APD batch assignment via API.
23. Jun 2016 11:48:47 CEST Tobias Imported from Hamamatsu datasheet.