RUB » Physics » The Faculty » Chairs and Working Groups » EP1 » PANDA FEMC Production Database

Show Hamamatsu Avalanche Photo Diode 0716006576 - Archived data from Fri, 16. April 2021 22:01:26 CEST


This is all the information about APD 0716006576. If it is wrong, edit the data.

Subdetector specification:  
Serial: 0716006576
Type: Hamamatsu Avalanche Photo Diode
Detector: unassigned
Unit: unassigned
Preamp: 0
Current location: Bochum
   
Installation information:  
Label: none
   
Manufacturer information:  
Wafer position: B04
Break-through voltage: 407 V
Voltage for Gain 100 (T=+25°C): 378.4 V
Dark current: 7.3 nA
   
Screening Logistics:  
Available: Yes
Storage Box: 364
Position in Box: 16
EP1 batch: none
EP1 batch after irradiation: none
   
Shipment:  
Grid number: none
Position in grid: none
Arrival for irradiation: none
Sent for analysis after irradiation: none
Return for assembly: none
   
Irradiation:  
Date: none
Dose used: none
Temperature: none
Position: none
Bias voltage: none     
   
Annealing:  
Date: none
Temperature: none
Duration: none
   
Measurement results:  
Voltage for Gain 100: T = +20 °C: 378.595876 V     T = -25 °C: 343.6412204 V
Voltage for Gain 150: T = +20 °C: 386.3867311 V     T = -25 °C: 350.8577064 V
Voltage for Gain 200: T = +20 °C: 390.7432989 V     T = -25 °C: 354.9222955 V
Gain/Voltage slope at M = 100: T = +20 °C: 4.754278474 V-1     T = -25 °C: 5.194019066 V-1
Gain/Voltage slope at M = 150: T = +20 °C: 8.552364419 V-1     T = -25 °C: 9.689604561 V-1
Gain/Voltage slope at M = 200: T = +20 °C: 14.69397981 V-1     T = -25 °C: 15.41307291 V-1
Break-through voltage: T = +20 °C: 403.4695855 V     T = -25 °C: 370.1795644 V
   
Notes:


Version history

Time Author Change comment
17. Jun 2021 18:45:31 CEST oafedulidis Assigned to capsule by script
16. Apr 2021 22:01:26 CEST jreher Updated APD characteristics via API.
05. Feb 2021 11:34:59 CET jreher Updated box and position via API.
18. Dec 2020 14:01:19 CET jreher Updated box and position via API.
08. Oct 2020 18:16:54 CEST jreher Updated APD location via API.
08. Sep 2020 16:25:46 CEST vwerner Updated APD batch assignment via API.
22. Jun 2016 15:13:14 CEST Tobias Imported from Hamamatsu datasheet.