RUB » Physics » The Faculty » Chairs and Working Groups » EP1 » PANDA FEMC Production Database

Show Hamamatsu Avalanche Photo Diode 1804020317 - Archived data from Tue, 11. August 2020 18:09:57 CEST


This is all the information about APD 1804020317. If it is wrong, edit the data.

Subdetector specification:  
Serial: 1804020317
Type: Hamamatsu Avalanche Photo Diode
Detector: unassigned
Unit: unassigned
Preamp: 0
Current location: Bochum
   
Installation information:  
Label: none
   
Manufacturer information:  
Wafer position: G10
Break-through voltage: 427 V
Voltage for Gain 100 (T=+25°C): 398.7 V
Dark current: 5.3 nA
   
Screening Logistics:  
Available: Yes
Storage Box: 269
Position in Box: 20
EP1 batch: none
EP1 batch after irradiation: none
   
Shipment:  
Grid number: none
Position in grid: none
Arrival for irradiation: none
Sent for analysis after irradiation: none
Return for assembly: none
   
Irradiation:  
Date: none
Dose used: none
Temperature: none
Position: none
Bias voltage: none     
   
Annealing:  
Date: none
Temperature: none
Duration: none
   
Measurement results:  
Voltage for Gain 100: T = +20 °C: 9.007857914 V     T = -25 °C: 362.0903631 V
Voltage for Gain 150: T = +20 °C: 9.159217363 V     T = -25 °C: 370.1043367 V
Voltage for Gain 200: T = +20 °C: 9.310576813 V     T = -25 °C: 374.5832761 V
Gain/Voltage slope at M = 100: T = +20 °C: 330.3394687 V-1     T = -25 °C: 4.470333945 V-1
Gain/Voltage slope at M = 150: T = +20 °C: 330.3394687 V-1     T = -25 °C: 8.590534541 V-1
Gain/Voltage slope at M = 200: T = +20 °C: 330.3394687 V-1     T = -25 °C: 14.64032809 V-1
Break-through voltage: T = +20 °C: 425.7951072 V     T = -25 °C: 391.0334688 V
   
Notes:


Version history

Time Author Change comment
05. Feb 2021 11:23:00 CET jreher Updated box and position via API.
11. Aug 2020 18:09:57 CEST jreher Updated APD characteristics via API.
21. Jul 2020 14:36:08 CEST jreher Updated APD location via API.
21. Jul 2020 14:35:58 CEST jreher Updated box and position via API.
29. Jun 2020 16:12:23 CEST jreher Updated APD batch assignment via API.
23. Jun 2016 11:48:45 CEST Tobias Imported from Hamamatsu datasheet.