Show Hamamatsu Avalanche Photo Diode 1804020300 - Archived data from Tue, 11. August 2020 18:08:48 CEST


This is all the information about APD 1804020300. If it is wrong, edit the data.

Subdetector specification:  
Serial: 1804020300
Type: Hamamatsu Avalanche Photo Diode
Detector: unassigned
Unit: unassigned
Preamp: 0
Current location: Bochum
   
Installation information:  
Label: none
   
Manufacturer information:  
Wafer position: B11
Break-through voltage: 432 V
Voltage for Gain 100 (T=+25°C): 404.3 V
Dark current: 5.9 nA
   
Screening Logistics:  
Available: Yes
Storage Box: 330
Position in Box: 16
EP1 batch: none
EP1 batch after irradiation: none
   
Shipment:  
Grid number: none
Position in grid: none
Arrival for irradiation: none
Sent for analysis after irradiation: none
Return for assembly: none
   
Irradiation:  
Date: none
Dose used: none
Temperature: none
Position: none
Bias voltage: none     
   
Annealing:  
Date: none
Temperature: none
Duration: none
   
Measurement results:  
Voltage for Gain 100: T = +20 °C: 394.1655757 V     T = -25 °C: 367.5051733 V
Voltage for Gain 150: T = +20 °C: 404.2970198 V     T = -25 °C: 375.3402821 V
Voltage for Gain 200: T = +20 °C: 410.0523368 V     T = -25 °C: 379.6873575 V
Gain/Voltage slope at M = 100: T = +20 °C: 3.571385259 V-1     T = -25 °C: 4.436605607 V-1
Gain/Voltage slope at M = 150: T = +20 °C: 6.772421771 V-1     T = -25 °C: 8.710520506 V-1
Gain/Voltage slope at M = 200: T = +20 °C: 11.05096064 V-1     T = -25 °C: 15.184769 V-1
Break-through voltage: T = +20 °C: 431.5930835 V     T = -25 °C: 395.4543563 V
   
Notes:


Version history

Time Author Change comment
05. Feb 2021 11:30:41 CET jreher Updated box and position via API.
11. Aug 2020 18:08:48 CEST jreher Updated APD characteristics via API.
21. Jul 2020 14:46:20 CEST jreher Updated APD location via API.
21. Jul 2020 14:46:11 CEST jreher Updated box and position via API.
29. Jun 2020 16:08:04 CEST jreher Updated APD batch assignment via API.
23. Jun 2016 11:48:45 CEST Tobias Imported from Hamamatsu datasheet.