RUB » Physics » The Faculty » Chairs and Working Groups » EP1 » PANDA FEMC Production Database

Show Hamamatsu Avalanche Photo Diode 1804020288 - Archived data from Tue, 11. August 2020 18:08:46 CEST


This is all the information about APD 1804020288. If it is wrong, edit the data.

Subdetector specification:  
Serial: 1804020288
Type: Hamamatsu Avalanche Photo Diode
Detector: unassigned
Unit: unassigned
Preamp: 0
Current location: Bochum
   
Installation information:  
Label: none
   
Manufacturer information:  
Wafer position: D13
Break-through voltage: 430 V
Voltage for Gain 100 (T=+25°C): 402.2 V
Dark current: 4.6 nA
   
Screening Logistics:  
Available: Yes
Storage Box: 330
Position in Box: 5
EP1 batch: none
EP1 batch after irradiation: none
   
Shipment:  
Grid number: none
Position in grid: none
Arrival for irradiation: none
Sent for analysis after irradiation: none
Return for assembly: none
   
Irradiation:  
Date: none
Dose used: none
Temperature: none
Position: none
Bias voltage: none     
   
Annealing:  
Date: none
Temperature: none
Duration: none
   
Measurement results:  
Voltage for Gain 100: T = +20 °C: 398.488707 V     T = -25 °C: 365.8670767 V
Voltage for Gain 150: T = +20 °C: 407.2151275 V     T = -25 °C: 373.6568078 V
Voltage for Gain 200: T = +20 °C: 412.1005918 V     T = -25 °C: 377.9758613 V
Gain/Voltage slope at M = 100: T = +20 °C: 4.083955917 V-1     T = -25 °C: 4.731639039 V-1
Gain/Voltage slope at M = 150: T = +20 °C: 7.992084458 V-1     T = -25 °C: 8.584600978 V-1
Gain/Voltage slope at M = 200: T = +20 °C: 13.15459621 V-1     T = -25 °C: 15.02846939 V-1
Break-through voltage: T = +20 °C: 429.5625835 V     T = -25 °C: 393.7040609 V
   
Notes:


Version history

Time Author Change comment
05. Feb 2021 11:30:40 CET jreher Updated box and position via API.
11. Aug 2020 18:08:46 CEST jreher Updated APD characteristics via API.
21. Jul 2020 14:46:19 CEST jreher Updated APD location via API.
21. Jul 2020 14:46:10 CEST jreher Updated box and position via API.
29. Jun 2020 16:08:03 CEST jreher Updated APD batch assignment via API.
23. Jun 2016 11:48:45 CEST Tobias Imported from Hamamatsu datasheet.