RUB » Physics » The Faculty » Chairs and Working Groups » EP1 » PANDA FEMC Production Database

Show Hamamatsu Avalanche Photo Diode 1803020209 - Archived data from Tue, 11. August 2020 17:34:02 CEST


This is all the information about APD 1803020209. If it is wrong, edit the data.

Subdetector specification:  
Serial: 1803020209
Type: Hamamatsu Avalanche Photo Diode
Detector: unassigned
Unit: unassigned
Preamp: 0
Current location: Bochum
   
Installation information:  
Label: none
   
Manufacturer information:  
Wafer position: C11
Break-through voltage: 428 V
Voltage for Gain 100 (T=+25°C): 399.4 V
Dark current: 4.3 nA
   
Screening Logistics:  
Available: Yes
Storage Box: 187
Position in Box: 31
EP1 batch: none
EP1 batch after irradiation: none
   
Shipment:  
Grid number: none
Position in grid: none
Arrival for irradiation: 18. Apr 2019
Sent for analysis after irradiation: 29. Jul 2019
Return for assembly: none
   
Irradiation:  
Date: 25. Jul 2019
Dose used: 37 Gy
Temperature: 20 °C
Position: none
Bias voltage: none     
   
Annealing:  
Date: 27. Jul 2019
Temperature: 80 °C
Duration: 48 h
   
Measurement results:  
Voltage for Gain 100: T = +20 °C: 400.3879335 V     T = -25 °C: 363.6675018 V
Voltage for Gain 150: T = +20 °C: 408.2980451 V     T = -25 °C: 371.5009241 V
Voltage for Gain 200: T = +20 °C: 412.6849563 V     T = -25 °C: 375.8605226 V
Gain/Voltage slope at M = 100: T = +20 °C: 4.454557441 V-1     T = -25 °C: 4.404057499 V-1
Gain/Voltage slope at M = 150: T = +20 °C: 8.692965578 V-1     T = -25 °C: 8.585842518 V-1
Gain/Voltage slope at M = 200: T = +20 °C: 15.13287277 V-1     T = -25 °C: 14.92377365 V-1
Break-through voltage: T = +20 °C: 427.415561 V     T = -25 °C: 391.2445238 V
   
Notes:


Version history

Time Author Change comment
05. Feb 2021 11:12:28 CET jreher Updated box and position via API.
11. Aug 2020 17:34:02 CEST jreher Updated APD characteristics via API.
27. Nov 2019 20:02:07 CET jreher Updated APD location via API.
25. Nov 2019 17:25:37 CET jreher Updated box and position via API.
13. Aug 2019 12:17:03 CEST jreher Updated APD location via API.
05. Aug 2019 17:05:45 CEST jreher Updated APD batch assignment via API.
30. Jul 2019 13:22:59 CEST markus.moritz
23. Jun 2016 11:48:43 CEST Tobias Imported from Hamamatsu datasheet.