Subdetector specification:  
Serial: 1803020202
Type: Hamamatsu Avalanche Photo Diode
Detector: unassigned
Unit: unassigned
Preamp: 0
Current location: Bochum
   
Installation information:  
Label: none
   
Manufacturer information:  
Wafer position: H09
Break-through voltage: 420 V
Voltage for Gain 100 (T=+25°C): 391.8 V
Dark current: 3 nA
   
Screening Logistics:  
Available: Yes
Storage Box: 187
Position in Box: 8
EP1 batch: none
EP1 batch after irradiation: none
   
Shipment:  
Grid number: none
Position in grid: none
Arrival for irradiation: 18. Apr 2019
Sent for analysis after irradiation: 29. Jul 2019
Return for assembly: none
   
Irradiation:  
Date: 25. Jul 2019
Dose used: 37 Gy
Temperature: 20 °C
Position: none
Bias voltage: none     
   
Annealing:  
Date: 27. Jul 2019
Temperature: 80 °C
Duration: 48 h
   
Measurement results:  
Voltage for Gain 100: T = +20 °C: 393.5308085 V     T = -25 °C: 357.3020027 V
Voltage for Gain 150: T = +20 °C: 401.4207707 V     T = -25 °C: 365.0252287 V
Voltage for Gain 200: T = +20 °C: 405.7810218 V     T = -25 °C: 369.3624682 V
Gain/Voltage slope at M = 100: T = +20 °C: 4.375738393 V-1     T = -25 °C: 4.598862235 V-1
Gain/Voltage slope at M = 150: T = +20 °C: 8.572540501 V-1     T = -25 °C: 9.034299292 V-1
Gain/Voltage slope at M = 200: T = +20 °C: 14.89007992 V-1     T = -25 °C: 14.07379484 V-1
Break-through voltage: T = +20 °C: 417.2605346 V     T = -25 °C: 383.1406139 V
   
Notes:


Version history

Time Author Change comment
05. Feb 2021 11:12:26 CET jreher Updated box and position via API.
11. Aug 2020 17:33:57 CEST jreher Updated APD characteristics via API.
27. Nov 2019 20:02:05 CET jreher Updated APD location via API.
25. Nov 2019 17:25:35 CET jreher Updated box and position via API.
13. Aug 2019 12:17:01 CEST jreher Updated APD location via API.
05. Aug 2019 17:05:54 CEST jreher Updated APD batch assignment via API.
30. Jul 2019 13:54:35 CEST markus.moritz
23. Jun 2016 11:48:43 CEST Tobias Imported from Hamamatsu datasheet.