RUB » Physics » The Faculty » Chairs and Working Groups » EP1 » PANDA FEMC Production Database

Show Hamamatsu Avalanche Photo Diode 1803020182 - Archived data from Tue, 11. August 2020 17:34:48 CEST


This is all the information about APD 1803020182. If it is wrong, edit the data.

Subdetector specification:  
Serial: 1803020182
Type: Hamamatsu Avalanche Photo Diode
Detector: unassigned
Unit: unassigned
Preamp: 0
Current location: Bochum
   
Installation information:  
Label: none
   
Manufacturer information:  
Wafer position: E09
Break-through voltage: 421 V
Voltage for Gain 100 (T=+25°C): 392.2 V
Dark current: 4.8 nA
   
Screening Logistics:  
Available: Yes
Storage Box: 190
Position in Box: 5
EP1 batch: none
EP1 batch after irradiation: none
   
Shipment:  
Grid number: none
Position in grid: none
Arrival for irradiation: 18. Apr 2019
Sent for analysis after irradiation: 29. Jul 2019
Return for assembly: none
   
Irradiation:  
Date: 25. Jul 2019
Dose used: 37 Gy
Temperature: 20 °C
Position: none
Bias voltage: none     
   
Annealing:  
Date: 27. Jul 2019
Temperature: 80 °C
Duration: 48 h
   
Measurement results:  
Voltage for Gain 100: T = +20 °C: 392.5947841 V     T = -25 °C: 356.1475022 V
Voltage for Gain 150: T = +20 °C: 400.5268743 V     T = -25 °C: 363.8277689 V
Voltage for Gain 200: T = +20 °C: 404.9174897 V     T = -25 °C: 368.1402529 V
Gain/Voltage slope at M = 100: T = +20 °C: 4.358921843 V-1     T = -25 °C: 4.687388485 V-1
Gain/Voltage slope at M = 150: T = +20 °C: 8.452389547 V-1     T = -25 °C: 9.251693812 V-1
Gain/Voltage slope at M = 200: T = +20 °C: 14.54628692 V-1     T = -25 °C: 14.40057545 V-1
Break-through voltage: T = +20 °C: 420.5182698 V     T = -25 °C: 383.964098 V
   
Notes:


Version history

Time Author Change comment
15. Nov 2022 12:55:42 CET oafedulidis Assigned to capsule by script
30. Aug 2021 14:07:38 CEST oafedulidis Updated box and position via API.
21. Apr 2021 14:03:42 CEST jreher Updated box and position via API.
21. Apr 2021 13:59:45 CEST jreher Updated box and position via API.
05. Feb 2021 11:12:49 CET jreher Updated box and position via API.
11. Aug 2020 17:34:48 CEST jreher Updated APD characteristics via API.
27. Nov 2019 20:02:38 CET jreher Updated APD location via API.
25. Nov 2019 17:25:49 CET jreher Updated box and position via API.
13. Aug 2019 12:17:27 CEST jreher Updated APD location via API.
09. Aug 2019 16:59:37 CEST spankonin Updated APD batch assignment via API.
30. Jul 2019 15:51:03 CEST markus.moritz
23. Jun 2016 11:47:42 CEST Tobias Imported from Hamamatsu datasheet.