RUB » Physics » The Faculty » Chairs and Working Groups » EP1 » PANDA FEMC Production Database

Show Hamamatsu Avalanche Photo Diode 1802020064 - Archived data from Tue, 11. August 2020 18:10:14 CEST


This is all the information about APD 1802020064. If it is wrong, edit the data.

Subdetector specification:  
Serial: 1802020064
Type: Hamamatsu Avalanche Photo Diode
Detector: unassigned
Unit: unassigned
Preamp: 0
Current location: Bochum
   
Installation information:  
Label: none
   
Manufacturer information:  
Wafer position: B08
Break-through voltage: 428 V
Voltage for Gain 100 (T=+25°C): 399.1 V
Dark current: 6.1 nA
   
Screening Logistics:  
Available: Yes
Storage Box: 241
Position in Box: 4
EP1 batch: none
EP1 batch after irradiation: none
   
Shipment:  
Grid number: none
Position in grid: none
Arrival for irradiation: none
Sent for analysis after irradiation: none
Return for assembly: none
   
Irradiation:  
Date: none
Dose used: none
Temperature: none
Position: none
Bias voltage: none     
   
Annealing:  
Date: none
Temperature: none
Duration: none
   
Measurement results:  
Voltage for Gain 100: T = +20 °C: 399.9743535 V     T = -25 °C: 363.2808195 V
Voltage for Gain 150: T = +20 °C: 407.8702163 V     T = -25 °C: 371.0947985 V
Voltage for Gain 200: T = +20 °C: 412.2518443 V     T = -25 °C: 375.4635505 V
Gain/Voltage slope at M = 100: T = +20 °C: 4.573557727 V-1     T = -25 °C: 4.54851177 V-1
Gain/Voltage slope at M = 150: T = +20 °C: 9.084138868 V-1     T = -25 °C: 8.937824492 V-1
Gain/Voltage slope at M = 200: T = +20 °C: 14.14380824 V-1     T = -25 °C: 13.8493768 V-1
Break-through voltage: T = +20 °C: 427.569319 V     T = -25 °C: 391.2542419 V
   
Notes:


Version history

Time Author Change comment
05. Feb 2021 11:19:20 CET jreher Updated box and position via API.
11. Aug 2020 18:10:14 CEST jreher Updated APD characteristics via API.
21. Jul 2020 14:31:18 CEST jreher Updated APD location via API.
21. Jul 2020 14:31:08 CEST jreher Updated box and position via API.
29. Jun 2020 16:14:06 CEST jreher Updated APD batch assignment via API.
23. Jun 2016 11:47:38 CEST Tobias Imported from Hamamatsu datasheet.