RUB » Physics » The Faculty » Chairs and Working Groups » EP1 » PANDA FEMC Production Database

Show Hamamatsu Avalanche Photo Diode 1801020040 - Archived data from Tue, 11. August 2020 18:10:23 CEST


This is all the information about APD 1801020040. If it is wrong, edit the data.

Subdetector specification:  
Serial: 1801020040
Type: Hamamatsu Avalanche Photo Diode
Detector: unassigned
Unit: unassigned
Preamp: 0
Current location: Bochum
   
Installation information:  
Label: none
   
Manufacturer information:  
Wafer position: E02
Break-through voltage: 413 V
Voltage for Gain 100 (T=+25°C): 384.5 V
Dark current: 5.5 nA
   
Screening Logistics:  
Available: Yes
Storage Box: 241
Position in Box: 48
EP1 batch: none
EP1 batch after irradiation: none
   
Shipment:  
Grid number: none
Position in grid: none
Arrival for irradiation: none
Sent for analysis after irradiation: none
Return for assembly: none
   
Irradiation:  
Date: none
Dose used: none
Temperature: none
Position: none
Bias voltage: none     
   
Annealing:  
Date: none
Temperature: none
Duration: none
   
Measurement results:  
Voltage for Gain 100: T = +20 °C: 1.042781397 V     T = -25 °C: 348.9780061 V
Voltage for Gain 150: T = +20 °C: 1.042781397 V     T = -25 °C: 356.6534135 V
Voltage for Gain 200: T = +20 °C: 1.042781397 V     T = -25 °C: 360.9551704 V
Gain/Voltage slope at M = 100: T = +20 °C: -609.0583778 V-1     T = -25 °C: 4.75420427 V-1
Gain/Voltage slope at M = 150: T = +20 °C: -609.0583778 V-1     T = -25 °C: 9.490997078 V-1
Gain/Voltage slope at M = 200: T = +20 °C: -609.0583778 V-1     T = -25 °C: 14.76343231 V-1
Break-through voltage: T = +20 °C: 411.9817722 V     T = -25 °C: 375.8550419 V
   
Notes:


Version history

Time Author Change comment
05. Feb 2021 11:19:25 CET jreher Updated box and position via API.
11. Aug 2020 18:10:23 CEST jreher Updated APD characteristics via API.
21. Jul 2020 16:15:42 CEST jreher Updated APD batch assignment via API.
21. Jul 2020 14:31:22 CEST jreher Updated APD location via API.
21. Jul 2020 14:31:12 CEST jreher Updated box and position via API.
23. Jun 2016 11:47:38 CEST Tobias Imported from Hamamatsu datasheet.