RUB » Physics » The Faculty » Chairs and Working Groups » EP1 » PANDA FEMC Production Database

Show Hamamatsu Avalanche Photo Diode 1801020031 - Archived data from Tue, 11. August 2020 18:10:21 CEST


This is all the information about APD 1801020031. If it is wrong, edit the data.

Subdetector specification:  
Serial: 1801020031
Type: Hamamatsu Avalanche Photo Diode
Detector: unassigned
Unit: unassigned
Preamp: 0
Current location: Bochum
   
Installation information:  
Label: none
   
Manufacturer information:  
Wafer position: D05
Break-through voltage: 419 V
Voltage for Gain 100 (T=+25°C): 390.4 V
Dark current: 6.4 nA
   
Screening Logistics:  
Available: Yes
Storage Box: 241
Position in Box: 40
EP1 batch: none
EP1 batch after irradiation: none
   
Shipment:  
Grid number: none
Position in grid: none
Arrival for irradiation: none
Sent for analysis after irradiation: none
Return for assembly: none
   
Irradiation:  
Date: none
Dose used: none
Temperature: none
Position: none
Bias voltage: none     
   
Annealing:  
Date: none
Temperature: none
Duration: none
   
Measurement results:  
Voltage for Gain 100: T = +20 °C: 391.1907383 V     T = -25 °C: 354.8784969 V
Voltage for Gain 150: T = +20 °C: 399.0953494 V     T = -25 °C: 362.5244409 V
Voltage for Gain 200: T = +20 °C: 403.4787981 V     T = -25 °C: 366.8100455 V
Gain/Voltage slope at M = 100: T = +20 °C: 4.468540531 V-1     T = -25 °C: 4.768791975 V-1
Gain/Voltage slope at M = 150: T = +20 °C: 8.741337716 V-1     T = -25 °C: 9.483980759 V-1
Gain/Voltage slope at M = 200: T = +20 °C: 15.1407283 V-1     T = -25 °C: 14.78203445 V-1
Break-through voltage: T = +20 °C: 418.9973976 V     T = -25 °C: 382.5480867 V
   
Notes:


Version history

Time Author Change comment
05. Feb 2021 11:19:24 CET jreher Updated box and position via API.
11. Aug 2020 18:10:21 CEST jreher Updated APD characteristics via API.
21. Jul 2020 14:31:21 CEST jreher Updated APD location via API.
21. Jul 2020 14:31:11 CEST jreher Updated box and position via API.
29. Jun 2020 16:14:27 CEST jreher Updated APD batch assignment via API.
23. Jun 2016 11:47:38 CEST Tobias Imported from Hamamatsu datasheet.