RUB » Physics » The Faculty » Chairs and Working Groups » EP1 » PANDA FEMC Production Database

Show Hamamatsu Avalanche Photo Diode 1801020007 - Archived data from Tue, 11. August 2020 18:10:16 CEST


This is all the information about APD 1801020007. If it is wrong, edit the data.

Subdetector specification:  
Serial: 1801020007
Type: Hamamatsu Avalanche Photo Diode
Detector: unassigned
Unit: unassigned
Preamp: 0
Current location: Bochum
   
Installation information:  
Label: none
   
Manufacturer information:  
Wafer position: D06
Break-through voltage: 419 V
Voltage for Gain 100 (T=+25°C): 390.1 V
Dark current: 7.5 nA
   
Screening Logistics:  
Available: Yes
Storage Box: 241
Position in Box: 16
EP1 batch: none
EP1 batch after irradiation: none
   
Shipment:  
Grid number: none
Position in grid: none
Arrival for irradiation: none
Sent for analysis after irradiation: none
Return for assembly: none
   
Irradiation:  
Date: none
Dose used: none
Temperature: none
Position: none
Bias voltage: none     
   
Annealing:  
Date: none
Temperature: none
Duration: none
   
Measurement results:  
Voltage for Gain 100: T = +20 °C: 390.8224336 V     T = -25 °C: 354.3163784 V
Voltage for Gain 150: T = +20 °C: 398.7267585 V     T = -25 °C: 361.9050671 V
Voltage for Gain 200: T = +20 °C: 403.0872302 V     T = -25 °C: 366.1587051 V
Gain/Voltage slope at M = 100: T = +20 °C: 4.667282769 V-1     T = -25 °C: 4.712251177 V-1
Gain/Voltage slope at M = 150: T = +20 °C: 9.331486537 V-1     T = -25 °C: 9.425367712 V-1
Gain/Voltage slope at M = 200: T = +20 °C: 14.60879248 V-1     T = -25 °C: 14.84458641 V-1
Break-through voltage: T = +20 °C: 418.7754672 V     T = -25 °C: 381.8376239 V
   
Notes:


Version history

Time Author Change comment
05. Feb 2021 11:19:21 CET jreher Updated box and position via API.
11. Aug 2020 18:10:16 CEST jreher Updated APD characteristics via API.
21. Jul 2020 14:31:19 CEST jreher Updated APD location via API.
21. Jul 2020 14:31:09 CEST jreher Updated box and position via API.
29. Jun 2020 16:14:25 CEST jreher Updated APD batch assignment via API.
23. Jun 2016 11:47:37 CEST Tobias Imported from Hamamatsu datasheet.