RUB » Physics » The Faculty » Chairs and Working Groups » EP1 » PANDA FEMC Production Database

Show Hamamatsu Avalanche Photo Diode 1718019752 - Archived data from Tue, 11. August 2020 17:50:02 CEST


This is all the information about APD 1718019752. If it is wrong, edit the data.

Subdetector specification:  
Serial: 1718019752
Type: Hamamatsu Avalanche Photo Diode
Detector: unassigned
Unit: unassigned
Preamp: 0
Current location: Bochum
   
Installation information:  
Label: none
   
Manufacturer information:  
Wafer position: G13
Break-through voltage: 429 V
Voltage for Gain 100 (T=+25°C): 401.7 V
Dark current: 5 nA
   
Screening Logistics:  
Available: Yes
Storage Box: 250
Position in Box: 13
EP1 batch: none
EP1 batch after irradiation: none
   
Shipment:  
Grid number: none
Position in grid: none
Arrival for irradiation: none
Sent for analysis after irradiation: none
Return for assembly: none
   
Irradiation:  
Date: none
Dose used: none
Temperature: none
Position: none
Bias voltage: none     
   
Annealing:  
Date: none
Temperature: none
Duration: none
   
Measurement results:  
Voltage for Gain 100: T = +20 °C: 402.5905721 V     T = -25 °C: 365.8367443 V
Voltage for Gain 150: T = +20 °C: 410.4662892 V     T = -25 °C: 373.634105 V
Voltage for Gain 200: T = +20 °C: 414.8299239 V     T = -25 °C: 377.9526076 V
Gain/Voltage slope at M = 100: T = +20 °C: 4.394501223 V-1     T = -25 °C: 4.712821233 V-1
Gain/Voltage slope at M = 150: T = +20 °C: 8.570352444 V-1     T = -25 °C: 9.403633577 V-1
Gain/Voltage slope at M = 200: T = +20 °C: 14.87726845 V-1     T = -25 °C: 14.76592196 V-1
Break-through voltage: T = +20 °C: 428.9114229 V     T = -25 °C: 392.5448997 V
   
Notes:


Version history

Time Author Change comment
05. Feb 2021 11:20:27 CET jreher Updated box and position via API.
11. Aug 2020 17:50:02 CEST jreher Updated APD characteristics via API.
21. Jul 2020 14:32:29 CEST jreher Updated box and position via API.
03. Dec 2019 14:47:29 CET jreher Updated APD location via API.
02. Dec 2019 19:17:15 CET spankonin Updated box and position via API.
02. Dec 2019 19:16:31 CET spankonin Updated APD batch assignment via API.
23. Jun 2016 11:43:41 CEST Tobias Imported from Hamamatsu datasheet.