RUB » Physics » The Faculty » Chairs and Working Groups » EP1 » PANDA FEMC Production Database

Show Hamamatsu Avalanche Photo Diode 1718019741 - Archived data from Tue, 11. August 2020 17:50:00 CEST


This is all the information about APD 1718019741. If it is wrong, edit the data.

Subdetector specification:  
Serial: 1718019741
Type: Hamamatsu Avalanche Photo Diode
Detector: unassigned
Unit: unassigned
Preamp: 0
Current location: Bochum
   
Installation information:  
Label: none
   
Manufacturer information:  
Wafer position: H09
Break-through voltage: 427 V
Voltage for Gain 100 (T=+25°C): 398.6 V
Dark current: 5 nA
   
Screening Logistics:  
Available: Yes
Storage Box: 250
Position in Box: 3
EP1 batch: none
EP1 batch after irradiation: none
   
Shipment:  
Grid number: none
Position in grid: none
Arrival for irradiation: none
Sent for analysis after irradiation: none
Return for assembly: none
   
Irradiation:  
Date: none
Dose used: none
Temperature: none
Position: none
Bias voltage: none     
   
Annealing:  
Date: none
Temperature: none
Duration: none
   
Measurement results:  
Voltage for Gain 100: T = +20 °C: 400.0170259 V     T = -25 °C: 363.3856833 V
Voltage for Gain 150: T = +20 °C: 407.8766214 V     T = -25 °C: 371.1369063 V
Voltage for Gain 200: T = +20 °C: 412.2449027 V     T = -25 °C: 375.4642535 V
Gain/Voltage slope at M = 100: T = +20 °C: 4.578996939 V-1     T = -25 °C: 4.559203426 V-1
Gain/Voltage slope at M = 150: T = +20 °C: 9.098723072 V-1     T = -25 °C: 8.962513459 V-1
Gain/Voltage slope at M = 200: T = +20 °C: 14.14053856 V-1     T = -25 °C: 15.83001338 V-1
Break-through voltage: T = +20 °C: 426.4383044 V     T = -25 °C: 389.9766741 V
   
Notes:


Version history

Time Author Change comment
05. Feb 2021 11:20:26 CET jreher Updated box and position via API.
11. Aug 2020 17:50:00 CEST jreher Updated APD characteristics via API.
21. Jul 2020 14:32:28 CEST jreher Updated box and position via API.
03. Dec 2019 14:47:28 CET jreher Updated APD location via API.
02. Dec 2019 19:17:14 CET spankonin Updated box and position via API.
02. Dec 2019 19:16:30 CET spankonin Updated APD batch assignment via API.
23. Jun 2016 11:43:41 CEST Tobias Imported from Hamamatsu datasheet.