Subdetector specification:  
Serial: 1715019554
Type: Hamamatsu Avalanche Photo Diode
Detector: unassigned
Unit: unassigned
Preamp: 0
Current location: Bochum
   
Installation information:  
Label: none
   
Manufacturer information:  
Wafer position: D13
Break-through voltage: 426 V
Voltage for Gain 100 (T=+25°C): 396.8 V
Dark current: 4.6 nA
   
Screening Logistics:  
Available: Yes
Storage Box: 277
Position in Box: 23
EP1 batch: none
EP1 batch after irradiation: none
   
Shipment:  
Grid number: none
Position in grid: none
Arrival for irradiation: none
Sent for analysis after irradiation: none
Return for assembly: none
   
Irradiation:  
Date: none
Dose used: none
Temperature: none
Position: none
Bias voltage: none     
   
Annealing:  
Date: none
Temperature: none
Duration: none
   
Measurement results:  
Voltage for Gain 100: T = +20 °C: 397.3922584 V     T = -25 °C: 361.1827512 V
Voltage for Gain 150: T = +20 °C: 405.3470504 V     T = -25 °C: 369.1789719 V
Voltage for Gain 200: T = +20 °C: 409.7653058 V     T = -25 °C: 373.6866033 V
Gain/Voltage slope at M = 100: T = +20 °C: 4.419975059 V-1     T = -25 °C: 4.574973486 V-1
Gain/Voltage slope at M = 150: T = +20 °C: 8.604723462 V-1     T = -25 °C: 8.597591682 V-1
Gain/Voltage slope at M = 200: T = +20 °C: 14.86677772 V-1     T = -25 °C: 14.42895269 V-1
Break-through voltage: T = +20 °C: 427.3969671 V     T = -25 °C: 388.8503534 V
   
Notes:


Version history

Time Author Change comment
05. Feb 2021 11:24:03 CET jreher Updated box and position via API.
11. Aug 2020 17:52:02 CEST jreher Updated APD characteristics via API.
21. Jul 2020 14:37:54 CEST jreher Updated APD location via API.
21. Jul 2020 14:37:45 CEST jreher Updated box and position via API.
12. Dec 2019 12:43:05 CET spankonin Updated box and position via API.
05. Dec 2019 18:00:43 CET spankonin Updated APD batch assignment via API.
23. Jun 2016 11:43:37 CEST Tobias Imported from Hamamatsu datasheet.