RUB » Physics » The Faculty » Chairs and Working Groups » EP1 » PANDA FEMC Production Database

Show Hamamatsu Avalanche Photo Diode 1715019541 - Archived data from Tue, 11. August 2020 17:52:27 CEST


This is all the information about APD 1715019541. If it is wrong, edit the data.

Subdetector specification:  
Serial: 1715019541
Type: Hamamatsu Avalanche Photo Diode
Detector: unassigned
Unit: unassigned
Preamp: 0
Current location: Bochum
   
Installation information:  
Label: none
   
Manufacturer information:  
Wafer position: F11
Break-through voltage: 421 V
Voltage for Gain 100 (T=+25°C): 392 V
Dark current: 4 nA
   
Screening Logistics:  
Available: Yes
Storage Box: 279
Position in Box: 40
EP1 batch: none
EP1 batch after irradiation: none
   
Shipment:  
Grid number: none
Position in grid: none
Arrival for irradiation: none
Sent for analysis after irradiation: none
Return for assembly: none
   
Irradiation:  
Date: none
Dose used: none
Temperature: none
Position: none
Bias voltage: none     
   
Annealing:  
Date: none
Temperature: none
Duration: none
   
Measurement results:  
Voltage for Gain 100: T = +20 °C: 392.8487292 V     T = -25 °C: 356.6692829 V
Voltage for Gain 150: T = +20 °C: 400.7203767 V     T = -25 °C: 364.4551526 V
Voltage for Gain 200: T = +20 °C: 405.0873579 V     T = -25 °C: 368.7857834 V
Gain/Voltage slope at M = 100: T = +20 °C: 4.622215926 V-1     T = -25 °C: 4.438369118 V-1
Gain/Voltage slope at M = 150: T = +20 °C: 9.196577993 V-1     T = -25 °C: 8.349038328 V-1
Gain/Voltage slope at M = 200: T = +20 °C: 14.31762325 V-1     T = -25 °C: 14.77762352 V-1
Break-through voltage: T = +20 °C: 416.9520495 V     T = -25 °C: 384.162428 V
   
Notes:


Version history

Time Author Change comment
05. Feb 2021 11:24:21 CET jreher Updated box and position via API.
11. Aug 2020 17:52:27 CEST jreher Updated APD characteristics via API.
21. Jul 2020 14:38:27 CEST jreher Updated APD location via API.
21. Jul 2020 14:38:16 CEST jreher Updated box and position via API.
12. Dec 2019 12:01:23 CET jreher Updated box and position via API.
05. Dec 2019 17:39:12 CET spankonin Updated APD batch assignment via API.
23. Jun 2016 11:43:36 CEST Tobias Imported from Hamamatsu datasheet.