RUB » Physics » The Faculty » Chairs and Working Groups » EP1 » PANDA FEMC Production Database

Show Hamamatsu Avalanche Photo Diode 1715019532 - Archived data from Tue, 11. August 2020 17:52:25 CEST


This is all the information about APD 1715019532. If it is wrong, edit the data.

Subdetector specification:  
Serial: 1715019532
Type: Hamamatsu Avalanche Photo Diode
Detector: unassigned
Unit: unassigned
Preamp: 0
Current location: Bochum
   
Installation information:  
Label: none
   
Manufacturer information:  
Wafer position: D02
Break-through voltage: 418 V
Voltage for Gain 100 (T=+25°C): 388.9 V
Dark current: 4.5 nA
   
Screening Logistics:  
Available: Yes
Storage Box: 279
Position in Box: 31
EP1 batch: none
EP1 batch after irradiation: none
   
Shipment:  
Grid number: none
Position in grid: none
Arrival for irradiation: none
Sent for analysis after irradiation: none
Return for assembly: none
   
Irradiation:  
Date: none
Dose used: none
Temperature: none
Position: none
Bias voltage: none     
   
Annealing:  
Date: none
Temperature: none
Duration: none
   
Measurement results:  
Voltage for Gain 100: T = +20 °C: 389.7079536 V     T = -25 °C: 353.3870154 V
Voltage for Gain 150: T = +20 °C: 397.629169 V     T = -25 °C: 360.9845819 V
Voltage for Gain 200: T = +20 °C: 402.0265095 V     T = -25 °C: 365.2757801 V
Gain/Voltage slope at M = 100: T = +20 °C: 4.619575711 V-1     T = -25 °C: 4.609574274 V-1
Gain/Voltage slope at M = 150: T = +20 °C: 9.144108777 V-1     T = -25 °C: 9.093096302 V-1
Gain/Voltage slope at M = 200: T = +20 °C: 14.1707915 V-1     T = -25 °C: 15.89233941 V-1
Break-through voltage: T = +20 °C: 417.2634672 V     T = -25 °C: 380.8113753 V
   
Notes:


Version history

Time Author Change comment
05. Feb 2021 11:24:20 CET jreher Updated box and position via API.
11. Aug 2020 17:52:25 CEST jreher Updated APD characteristics via API.
21. Jul 2020 14:38:26 CEST jreher Updated APD location via API.
21. Jul 2020 14:38:16 CEST jreher Updated box and position via API.
12. Dec 2019 12:01:22 CET jreher Updated box and position via API.
05. Dec 2019 17:41:41 CET spankonin Updated APD batch assignment via API.
23. Jun 2016 11:43:36 CEST Tobias Imported from Hamamatsu datasheet.