RUB » Physics » The Faculty » Chairs and Working Groups » EP1 » PANDA FEMC Production Database

Show Hamamatsu Avalanche Photo Diode 1714019455 - Archived data from Tue, 11. August 2020 17:50:59 CEST


This is all the information about APD 1714019455. If it is wrong, edit the data.

Subdetector specification:  
Serial: 1714019455
Type: Hamamatsu Avalanche Photo Diode
Detector: unassigned
Unit: unassigned
Preamp: 0
Current location: Bochum
   
Installation information:  
Label: none
   
Manufacturer information:  
Wafer position: B07
Break-through voltage: 424 V
Voltage for Gain 100 (T=+25°C): 395.1 V
Dark current: 3.5 nA
   
Screening Logistics:  
Available: Yes
Storage Box: 266
Position in Box: 31
EP1 batch: none
EP1 batch after irradiation: none
   
Shipment:  
Grid number: none
Position in grid: none
Arrival for irradiation: none
Sent for analysis after irradiation: none
Return for assembly: none
   
Irradiation:  
Date: none
Dose used: none
Temperature: none
Position: none
Bias voltage: none     
   
Annealing:  
Date: none
Temperature: none
Duration: none
   
Measurement results:  
Voltage for Gain 100: T = +20 °C: 395.5520017 V     T = -25 °C: 360.0057209 V
Voltage for Gain 150: T = +20 °C: 403.4724048 V     T = -25 °C: 367.7981768 V
Voltage for Gain 200: T = +20 °C: 407.8559442 V     T = -25 °C: 372.2321402 V
Gain/Voltage slope at M = 100: T = +20 °C: 4.368000886 V-1     T = -25 °C: 4.476022287 V-1
Gain/Voltage slope at M = 150: T = +20 °C: 9.291024101 V-1     T = -25 °C: 8.777390982 V-1
Gain/Voltage slope at M = 200: T = +20 °C: 14.47355565 V-1     T = -25 °C: 13.62740377 V-1
Break-through voltage: T = +20 °C: 423.0397558 V     T = -25 °C: 388.2929675 V
   
Notes:


Version history

Time Author Change comment
05. Feb 2021 11:22:37 CET jreher Updated box and position via API.
11. Aug 2020 17:50:59 CEST jreher Updated APD characteristics via API.
21. Jul 2020 14:35:25 CEST jreher Updated box and position via API.
03. Dec 2019 14:45:30 CET jreher Updated APD location via API.
02. Dec 2019 19:19:47 CET spankonin Updated box and position via API.
02. Dec 2019 19:09:55 CET spankonin Updated APD batch assignment via API.
23. Jun 2016 11:43:34 CEST Tobias Imported from Hamamatsu datasheet.