RUB » Physics » The Faculty » Chairs and Working Groups » EP1 » PANDA FEMC Production Database

Show Hamamatsu Avalanche Photo Diode 1714019431 - Archived data from Tue, 11. August 2020 17:51:03 CEST


This is all the information about APD 1714019431. If it is wrong, edit the data.

Subdetector specification:  
Serial: 1714019431
Type: Hamamatsu Avalanche Photo Diode
Detector: unassigned
Unit: unassigned
Preamp: 0
Current location: Bochum
   
Installation information:  
Label: none
   
Manufacturer information:  
Wafer position: C14
Break-through voltage: 422 V
Voltage for Gain 100 (T=+25°C): 394.9 V
Dark current: 3.3 nA
   
Screening Logistics:  
Available: Yes
Storage Box: 266
Position in Box: 48
EP1 batch: none
EP1 batch after irradiation: none
   
Shipment:  
Grid number: none
Position in grid: none
Arrival for irradiation: none
Sent for analysis after irradiation: none
Return for assembly: none
   
Irradiation:  
Date: none
Dose used: none
Temperature: none
Position: none
Bias voltage: none     
   
Annealing:  
Date: none
Temperature: none
Duration: none
   
Measurement results:  
Voltage for Gain 100: T = +20 °C: 394.5368496 V     T = -25 °C: 358.4022368 V
Voltage for Gain 150: T = +20 °C: 402.4074547 V     T = -25 °C: 366.074817 V
Voltage for Gain 200: T = +20 °C: 406.7638276 V     T = -25 °C: 370.3826587 V
Gain/Voltage slope at M = 100: T = +20 °C: 4.41634261 V-1     T = -25 °C: 4.598044049 V-1
Gain/Voltage slope at M = 150: T = +20 °C: 8.625644142 V-1     T = -25 °C: 9.067904771 V-1
Gain/Voltage slope at M = 200: T = +20 °C: 14.9955279 V-1     T = -25 °C: 14.07139828 V-1
Break-through voltage: T = +20 °C: 419.3691756 V     T = -25 °C: 385.6830363 V
   
Notes:


Version history

Time Author Change comment
05. Feb 2021 11:22:39 CET jreher Updated box and position via API.
11. Aug 2020 17:51:03 CEST jreher Updated APD characteristics via API.
21. Jul 2020 14:35:26 CEST jreher Updated box and position via API.
03. Dec 2019 14:45:31 CET jreher Updated APD location via API.
02. Dec 2019 19:19:49 CET spankonin Updated box and position via API.
02. Dec 2019 19:09:56 CET spankonin Updated APD batch assignment via API.
23. Jun 2016 11:43:34 CEST Tobias Imported from Hamamatsu datasheet.