RUB » Physics » The Faculty » Chairs and Working Groups » EP1 » PANDA FEMC Production Database

Show Hamamatsu Avalanche Photo Diode 1713019371 - Archived data from Tue, 11. August 2020 17:50:36 CEST


This is all the information about APD 1713019371. If it is wrong, edit the data.

Subdetector specification:  
Serial: 1713019371
Type: Hamamatsu Avalanche Photo Diode
Detector: unassigned
Unit: unassigned
Preamp: 0
Current location: Bochum
   
Installation information:  
Label: none
   
Manufacturer information:  
Wafer position: G09
Break-through voltage: 419 V
Voltage for Gain 100 (T=+25°C): 390 V
Dark current: 3 nA
   
Screening Logistics:  
Available: Yes
Storage Box: 260
Position in Box: 25
EP1 batch: none
EP1 batch after irradiation: none
   
Shipment:  
Grid number: none
Position in grid: none
Arrival for irradiation: none
Sent for analysis after irradiation: none
Return for assembly: none
   
Irradiation:  
Date: none
Dose used: none
Temperature: none
Position: none
Bias voltage: none     
   
Annealing:  
Date: none
Temperature: none
Duration: none
   
Measurement results:  
Voltage for Gain 100: T = +20 °C: 390.9022242 V     T = -25 °C: 354.9787672 V
Voltage for Gain 150: T = +20 °C: 398.7661241 V     T = -25 °C: 362.5924946 V
Voltage for Gain 200: T = +20 °C: 403.128557 V     T = -25 °C: 366.8518941 V
Gain/Voltage slope at M = 100: T = +20 °C: 4.603100552 V-1     T = -25 °C: 4.838464847 V-1
Gain/Voltage slope at M = 150: T = +20 °C: 9.172550132 V-1     T = -25 °C: 9.639984751 V-1
Gain/Voltage slope at M = 200: T = +20 °C: 14.22207909 V-1     T = -25 °C: 15.01876854 V-1
Break-through voltage: T = +20 °C: 410.6038737 V     T = -25 °C: 382.5360055 V
   
Notes:


Version history

Time Author Change comment
26. Oct 2021 16:06:50 CEST oafedulidis Assigned to capsule by script
17. May 2021 09:16:07 CEST oafedulidis Updated box and position via API.
05. Feb 2021 11:21:48 CET jreher Updated box and position via API.
11. Aug 2020 17:50:36 CEST jreher Updated APD characteristics via API.
21. Jul 2020 14:34:18 CEST jreher Updated box and position via API.
05. Dec 2019 14:37:05 CET jreher Updated box and position via API.
05. Dec 2019 14:35:01 CET spankonin Updated box and position via API.
05. Dec 2019 14:33:04 CET spankonin Updated box and position via API.
03. Dec 2019 14:46:21 CET jreher Updated APD location via API.
02. Dec 2019 19:19:19 CET spankonin Updated box and position via API.
02. Dec 2019 19:13:39 CET spankonin Updated APD batch assignment via API.
23. Jun 2016 11:42:34 CEST Tobias Imported from Hamamatsu datasheet.