RUB » Physics » The Faculty » Chairs and Working Groups » EP1 » PANDA FEMC Production Database

Show Hamamatsu Avalanche Photo Diode 1712019287 - Archived data from Tue, 11. August 2020 17:51:09 CEST


This is all the information about APD 1712019287. If it is wrong, edit the data.

Subdetector specification:  
Serial: 1712019287
Type: Hamamatsu Avalanche Photo Diode
Detector: unassigned
Unit: unassigned
Preamp: 0
Current location: Bochum
   
Installation information:  
Label: none
   
Manufacturer information:  
Wafer position: E14
Break-through voltage: 421 V
Voltage for Gain 100 (T=+25°C): 394.3 V
Dark current: 3.7 nA
   
Screening Logistics:  
Available: Yes
Storage Box: 268
Position in Box: 31
EP1 batch: none
EP1 batch after irradiation: none
   
Shipment:  
Grid number: none
Position in grid: none
Arrival for irradiation: none
Sent for analysis after irradiation: none
Return for assembly: none
   
Irradiation:  
Date: none
Dose used: none
Temperature: none
Position: none
Bias voltage: none     
   
Annealing:  
Date: none
Temperature: none
Duration: none
   
Measurement results:  
Voltage for Gain 100: T = +20 °C: 393.6582602 V     T = -25 °C: 357.1722144 V
Voltage for Gain 150: T = +20 °C: 401.5989239 V     T = -25 °C: 364.8970185 V
Voltage for Gain 200: T = +20 °C: 406.0005916 V     T = -25 °C: 369.2355219 V
Gain/Voltage slope at M = 100: T = +20 °C: 4.633753979 V-1     T = -25 °C: 4.626414659 V-1
Gain/Voltage slope at M = 150: T = +20 °C: 9.169396082 V-1     T = -25 °C: 9.125647302 V-1
Gain/Voltage slope at M = 200: T = +20 °C: 14.30168597 V-1     T = -25 °C: 14.13496584 V-1
Break-through voltage: T = +20 °C: 420.7387944 V     T = -25 °C: 384.7086535 V
   
Notes:


Version history

Time Author Change comment
05. Feb 2021 11:22:53 CET jreher Updated box and position via API.
11. Aug 2020 17:51:09 CEST jreher Updated APD characteristics via API.
21. Jul 2020 14:35:49 CEST jreher Updated box and position via API.
03. Dec 2019 14:45:12 CET jreher Updated APD location via API.
02. Dec 2019 19:20:03 CET spankonin Updated box and position via API.
02. Dec 2019 19:08:30 CET spankonin Updated APD batch assignment via API.
23. Jun 2016 11:42:32 CEST Tobias Imported from Hamamatsu datasheet.