Show Hamamatsu Avalanche Photo Diode 1710019164 - Archived data from Tue, 11. August 2020 17:27:09 CEST
This is all the information about APD 1710019164. If it is wrong, edit the data.
Subdetector specification: | |
---|---|
Serial: | 1710019164 |
Type: | Hamamatsu Avalanche Photo Diode |
Detector: | unassigned |
Unit: | unassigned |
Preamp: | 0 |
Current location: | Bochum |
Installation information: | |
Label: | none |
Manufacturer information: | |
Wafer position: | F06 |
Break-through voltage: | 426 V |
Voltage for Gain 100 (T=+25°C): | 397.4 V |
Dark current: | 3.5 nA |
Screening Logistics: | |
Available: | Yes |
Storage Box: | 46 |
Position in Box: | 7 |
EP1 batch: | none |
EP1 batch after irradiation: | none |
Shipment: | |
Grid number: | 3003 |
Position in grid: | 3 |
Arrival for irradiation: | 11. Aug 2016 |
Sent for analysis after irradiation: | 02. Sep 2016 |
Return for assembly: | 13. Oct 2016 |
Irradiation: | |
Date: | 18. Aug 2016 |
Dose used: | 30 Gy |
Temperature: | 25 °C |
Position: | 2 |
Bias voltage: | 350 V (not connected) |
Annealing: | |
Date: | 18. Aug 2016 |
Temperature: | 80 °C |
Duration: | 10 h |
Measurement results: | |
Voltage for Gain 100: | T = +20 °C: 398.2505562 V T = -25 °C: 361.8946611 V |
Voltage for Gain 150: | T = +20 °C: 406.1773395 V T = -25 °C: 369.7375866 V |
Voltage for Gain 200: | T = +20 °C: 410.5625305 V T = -25 °C: 374.1740034 V |
Gain/Voltage slope at M = 100: | T = +20 °C: 4.54838341 V-1 T = -25 °C: 4.659583945 V-1 |
Gain/Voltage slope at M = 150: | T = +20 °C: 8.626686939 V-1 T = -25 °C: 8.932137992 V-1 |
Gain/Voltage slope at M = 200: | T = +20 °C: 15.36823482 V-1 T = -25 °C: 13.75676531 V-1 |
Break-through voltage: | T = +20 °C: 425.9611835 V T = -25 °C: 389.4295748 V |
Notes: |
Version history
Time | Author | Change comment |
---|---|---|
05. Feb 2021 10:54:04 CET | jreher | Updated box and position via API. |
03. Feb 2021 18:19:51 CET | jreher | Updated box and position via API. |
07. Oct 2020 15:46:07 CEST | jreher | Updated APD location via API. |
11. Aug 2020 17:27:09 CEST | jreher | Updated APD characteristics via API. |
27. Nov 2019 19:37:08 CET | jreher | Updated APD location via API. |
25. Nov 2019 17:14:32 CET | jreher | Updated box and position via API. |
04. Jul 2019 11:11:51 CEST | jreher | Updated APD location via API. |
18. Jun 2019 13:30:06 CEST | jgrochowski | Updated APD batch assignment via API. |
05. Apr 2018 14:03:48 CEST | jgrochowski | |
13. Oct 2016 11:50:18 CEST | markus.moritz | Entered return for assembly date. |
08. Sep 2016 13:37:21 CEST | markus.moritz | Entered shipped after irradiation date. |
24. Aug 2016 14:21:50 CEST | christopher.l.hahn | Entered annealing information. |
18. Aug 2016 11:39:27 CEST | markus.moritz | Entered irradiation information. |
11. Aug 2016 11:44:28 CEST | markus.moritz | Entered arrival for irradiation date. |
01. Aug 2016 17:52:15 CEST | Tobias | Assigned to grid via information extracted from APD DB. |
23. Jun 2016 11:42:29 CEST | Tobias | Imported from Hamamatsu datasheet. |