RUB » Physics » The Faculty » Chairs and Working Groups » EP1 » PANDA FEMC Production Database

Show Hamamatsu Avalanche Photo Diode 1710019132 - Archived data from Tue, 11. August 2020 17:52:51 CEST


This is all the information about APD 1710019132. If it is wrong, edit the data.

Subdetector specification:  
Serial: 1710019132
Type: Hamamatsu Avalanche Photo Diode
Detector: unassigned
Unit: unassigned
Preamp: 0
Current location: Bochum
   
Installation information:  
Label: none
   
Manufacturer information:  
Wafer position: B10
Break-through voltage: 428 V
Voltage for Gain 100 (T=+25°C): 398.8 V
Dark current: 3.6 nA
   
Screening Logistics:  
Available: Yes
Storage Box: 282
Position in Box: 2
EP1 batch: none
EP1 batch after irradiation: none
   
Shipment:  
Grid number: none
Position in grid: none
Arrival for irradiation: none
Sent for analysis after irradiation: none
Return for assembly: none
   
Irradiation:  
Date: none
Dose used: none
Temperature: none
Position: none
Bias voltage: none     
   
Annealing:  
Date: none
Temperature: none
Duration: none
   
Measurement results:  
Voltage for Gain 100: T = +20 °C: 399.8700556 V     T = -25 °C: 362.782823 V
Voltage for Gain 150: T = +20 °C: 407.7023135 V     T = -25 °C: 370.5808652 V
Voltage for Gain 200: T = +20 °C: 412.0379994 V     T = -25 °C: 374.9160407 V
Gain/Voltage slope at M = 100: T = +20 °C: 4.60631789 V-1     T = -25 °C: 4.700548718 V-1
Gain/Voltage slope at M = 150: T = +20 °C: 9.225910799 V-1     T = -25 °C: 9.370265938 V-1
Gain/Voltage slope at M = 200: T = +20 °C: 14.39155756 V-1     T = -25 °C: 14.50898005 V-1
Break-through voltage: T = +20 °C: 427.50369 V     T = -25 °C: 391.1011059 V
   
Notes:


Version history

Time Author Change comment
05. Feb 2021 11:24:40 CET jreher Updated box and position via API.
11. Aug 2020 17:52:51 CEST jreher Updated APD characteristics via API.
21. Jul 2020 14:39:08 CEST jreher Updated APD location via API.
21. Jul 2020 14:38:58 CEST jreher Updated box and position via API.
09. Dec 2019 18:29:12 CET spankonin Updated box and position via API.
09. Dec 2019 18:26:05 CET spankonin Updated APD batch assignment via API.
23. Jun 2016 11:42:28 CEST Tobias Imported from Hamamatsu datasheet.