RUB » Physics » The Faculty » Chairs and Working Groups » EP1 » PANDA FEMC Production Database

Show Hamamatsu Avalanche Photo Diode 1709019107 - Archived data from Tue, 11. August 2020 17:52:56 CEST


This is all the information about APD 1709019107. If it is wrong, edit the data.

Subdetector specification:  
Serial: 1709019107
Type: Hamamatsu Avalanche Photo Diode
Detector: unassigned
Unit: unassigned
Preamp: 0
Current location: Bochum
   
Installation information:  
Label: none
   
Manufacturer information:  
Wafer position: B12
Break-through voltage: 426 V
Voltage for Gain 100 (T=+25°C): 397.7 V
Dark current: 3.6 nA
   
Screening Logistics:  
Available: Yes
Storage Box: 282
Position in Box: 26
EP1 batch: none
EP1 batch after irradiation: none
   
Shipment:  
Grid number: none
Position in grid: none
Arrival for irradiation: none
Sent for analysis after irradiation: none
Return for assembly: none
   
Irradiation:  
Date: none
Dose used: none
Temperature: none
Position: none
Bias voltage: none     
   
Annealing:  
Date: none
Temperature: none
Duration: none
   
Measurement results:  
Voltage for Gain 100: T = +20 °C: 398.3830981 V     T = -25 °C: 361.3329559 V
Voltage for Gain 150: T = +20 °C: 406.2334756 V     T = -25 °C: 369.109121 V
Voltage for Gain 200: T = +20 °C: 410.5846308 V     T = -25 °C: 373.4623044 V
Gain/Voltage slope at M = 100: T = +20 °C: 4.461073851 V-1     T = -25 °C: 4.534989047 V-1
Gain/Voltage slope at M = 150: T = +20 °C: 8.724189004 V-1     T = -25 °C: 8.897147126 V-1
Gain/Voltage slope at M = 200: T = +20 °C: 15.25172399 V-1     T = -25 °C: 15.46157181 V-1
Break-through voltage: T = +20 °C: 426.1491251 V     T = -25 °C: 389.5423427 V
   
Notes:


Version history

Time Author Change comment
05. Feb 2021 11:24:43 CET jreher Updated box and position via API.
11. Aug 2020 17:52:56 CEST jreher Updated APD characteristics via API.
21. Jul 2020 14:39:10 CEST jreher Updated APD location via API.
21. Jul 2020 14:39:00 CEST jreher Updated box and position via API.
09. Dec 2019 18:29:13 CET spankonin Updated box and position via API.
09. Dec 2019 18:23:50 CET spankonin Updated APD batch assignment via API.
23. Jun 2016 11:42:27 CEST Tobias Imported from Hamamatsu datasheet.