RUB » Physics » The Faculty » Chairs and Working Groups » EP1 » PANDA FEMC Production Database

Show Hamamatsu Avalanche Photo Diode 1708019012 - Archived data from Tue, 11. August 2020 17:50:47 CEST


This is all the information about APD 1708019012. If it is wrong, edit the data.

Subdetector specification:  
Serial: 1708019012
Type: Hamamatsu Avalanche Photo Diode
Detector: unassigned
Unit: unassigned
Preamp: 0
Current location: Bochum
   
Installation information:  
Label: none
   
Manufacturer information:  
Wafer position: D14
Break-through voltage: 420 V
Voltage for Gain 100 (T=+25°C): 392.5 V
Dark current: 5.6 nA
   
Screening Logistics:  
Available: Yes
Storage Box: 264
Position in Box: 28
EP1 batch: none
EP1 batch after irradiation: none
   
Shipment:  
Grid number: none
Position in grid: none
Arrival for irradiation: none
Sent for analysis after irradiation: none
Return for assembly: none
   
Irradiation:  
Date: none
Dose used: none
Temperature: none
Position: none
Bias voltage: none     
   
Annealing:  
Date: none
Temperature: none
Duration: none
   
Measurement results:  
Voltage for Gain 100: T = +20 °C: 392.5445375 V     T = -25 °C: 356.5772186 V
Voltage for Gain 150: T = +20 °C: 400.4451031 V     T = -25 °C: 364.2815863 V
Voltage for Gain 200: T = +20 °C: 404.8179435 V     T = -25 °C: 368.4608034 V
Gain/Voltage slope at M = 100: T = +20 °C: 4.362345537 V-1     T = -25 °C: 5.26856818 V-1
Gain/Voltage slope at M = 150: T = +20 °C: 9.289708568 V-1     T = -25 °C: 8.499164088 V-1
Gain/Voltage slope at M = 200: T = +20 °C: 14.44530466 V-1     T = -25 °C: 14.70874612 V-1
Break-through voltage: T = +20 °C: 419.5027394 V     T = -25 °C: 383.2153166 V
   
Notes:


Version history

Time Author Change comment
05. Feb 2021 11:22:20 CET jreher Updated box and position via API.
11. Aug 2020 17:50:47 CEST jreher Updated APD characteristics via API.
21. Jul 2020 14:35:04 CEST jreher Updated box and position via API.
03. Dec 2019 14:46:00 CET jreher Updated APD location via API.
02. Dec 2019 19:19:34 CET spankonin Updated box and position via API.
02. Dec 2019 19:11:31 CET spankonin Updated APD batch assignment via API.
23. Jun 2016 11:42:25 CEST Tobias Imported from Hamamatsu datasheet.