RUB » Physics » The Faculty » Chairs and Working Groups » EP1 » PANDA FEMC Production Database

Show Hamamatsu Avalanche Photo Diode 1708018991 - Archived data from Tue, 11. August 2020 17:50:52 CEST


This is all the information about APD 1708018991. If it is wrong, edit the data.

Subdetector specification:  
Serial: 1708018991
Type: Hamamatsu Avalanche Photo Diode
Detector: unassigned
Unit: unassigned
Preamp: 0
Current location: Bochum
   
Installation information:  
Label: none
   
Manufacturer information:  
Wafer position: G08
Break-through voltage: 420 V
Voltage for Gain 100 (T=+25°C): 390.8 V
Dark current: 5 nA
   
Screening Logistics:  
Available: Yes
Storage Box: 264
Position in Box: 47
EP1 batch: none
EP1 batch after irradiation: none
   
Shipment:  
Grid number: none
Position in grid: none
Arrival for irradiation: none
Sent for analysis after irradiation: none
Return for assembly: none
   
Irradiation:  
Date: none
Dose used: none
Temperature: none
Position: none
Bias voltage: none     
   
Annealing:  
Date: none
Temperature: none
Duration: none
   
Measurement results:  
Voltage for Gain 100: T = +20 °C: 391.5621413 V     T = -25 °C: 355.4888581 V
Voltage for Gain 150: T = +20 °C: 399.4138343 V     T = -25 °C: 363.1060185 V
Voltage for Gain 200: T = +20 °C: 403.7664588 V     T = -25 °C: 367.377905 V
Gain/Voltage slope at M = 100: T = +20 °C: 4.433639301 V-1     T = -25 °C: 4.624337696 V-1
Gain/Voltage slope at M = 150: T = +20 °C: 8.662302736 V-1     T = -25 °C: 9.164189627 V-1
Gain/Voltage slope at M = 200: T = +20 °C: 15.07672545 V-1     T = -25 °C: 14.27595969 V-1
Break-through voltage: T = +20 °C: 412.6457822 V     T = -25 °C: 382.8467471 V
   
Notes:


Version history

Time Author Change comment
19. May 2022 15:29:24 CEST oafedulidis Assigned to capsule by script
27. Aug 2021 11:10:50 CEST oafedulidis Updated box and position via API.
05. Feb 2021 11:22:22 CET jreher Updated box and position via API.
11. Aug 2020 17:50:52 CEST jreher Updated APD characteristics via API.
21. Jul 2020 14:35:05 CEST jreher Updated box and position via API.
03. Dec 2019 14:46:02 CET jreher Updated APD location via API.
02. Dec 2019 19:19:36 CET spankonin Updated box and position via API.
02. Dec 2019 19:10:37 CET spankonin Updated APD batch assignment via API.
23. Jun 2016 11:42:24 CEST Tobias Imported from Hamamatsu datasheet.