RUB » Physics » The Faculty » Chairs and Working Groups » EP1 » PANDA FEMC Production Database

Show Hamamatsu Avalanche Photo Diode 1707018897 - Archived data from Tue, 11. August 2020 17:51:32 CEST


This is all the information about APD 1707018897. If it is wrong, edit the data.

Subdetector specification:  
Serial: 1707018897
Type: Hamamatsu Avalanche Photo Diode
Detector: unassigned
Unit: unassigned
Preamp: 0
Current location: Bochum
   
Installation information:  
Label: none
   
Manufacturer information:  
Wafer position: F07
Break-through voltage: 414 V
Voltage for Gain 100 (T=+25°C): 385.7 V
Dark current: 3.4 nA
   
Screening Logistics:  
Available: Yes
Storage Box: 273
Position in Box: 32
EP1 batch: none
EP1 batch after irradiation: none
   
Shipment:  
Grid number: none
Position in grid: none
Arrival for irradiation: none
Sent for analysis after irradiation: none
Return for assembly: none
   
Irradiation:  
Date: none
Dose used: none
Temperature: none
Position: none
Bias voltage: none     
   
Annealing:  
Date: none
Temperature: none
Duration: none
   
Measurement results:  
Voltage for Gain 100: T = +20 °C: 386.0158555 V     T = -25 °C: 350.2404201 V
Voltage for Gain 150: T = +20 °C: 393.844813 V     T = -25 °C: 357.7401903 V
Voltage for Gain 200: T = +20 °C: 398.1942793 V     T = -25 °C: 361.952354 V
Gain/Voltage slope at M = 100: T = +20 °C: 4.600115824 V-1     T = -25 °C: 4.744573022 V-1
Gain/Voltage slope at M = 150: T = +20 °C: 9.095830648 V-1     T = -25 °C: 9.535698194 V-1
Gain/Voltage slope at M = 200: T = +20 °C: 14.20879959 V-1     T = -25 °C: 14.95325382 V-1
Break-through voltage: T = +20 °C: 410.527003 V     T = -25 °C: 377.8835596 V
   
Notes:


Version history

Time Author Change comment
29. Mar 2022 12:38:40 CEST oafedulidis Assigned to capsule by script
16. Jun 2021 16:04:52 CEST oafedulidis Updated box and position via API.
16. Jun 2021 16:01:04 CEST oafedulidis Updated box and position via API.
16. Jun 2021 15:53:50 CEST oafedulidis Updated box and position via API.
05. Feb 2021 11:23:32 CET jreher Updated box and position via API.
11. Aug 2020 17:51:32 CEST jreher Updated APD characteristics via API.
21. Jul 2020 14:36:57 CEST jreher Updated APD location via API.
21. Jul 2020 14:36:48 CEST jreher Updated box and position via API.
12. Dec 2019 12:00:47 CET jreher Updated box and position via API.
09. Dec 2019 14:52:39 CET jreher Updated box and position via API.
05. Dec 2019 18:07:38 CET spankonin Updated APD batch assignment via API.
23. Jun 2016 11:42:22 CEST Tobias Imported from Hamamatsu datasheet.