Show Hamamatsu Avalanche Photo Diode 1704018676 - Archived data from Tue, 11. August 2020 17:58:06 CEST
This is all the information about APD 1704018676. If it is wrong, edit the data.
Subdetector specification: | |
---|---|
Serial: | 1704018676 |
Type: | Hamamatsu Avalanche Photo Diode |
Detector: | unassigned |
Unit: | unassigned |
Preamp: | 0 |
Current location: | Bochum |
Installation information: | |
Label: | none |
Manufacturer information: | |
Wafer position: | D08 |
Break-through voltage: | 420 V |
Voltage for Gain 100 (T=+25°C): | 390.4 V |
Dark current: | 4.5 nA |
Screening Logistics: | |
Available: | Yes |
Storage Box: | 305 |
Position in Box: | 46 |
EP1 batch: | none |
EP1 batch after irradiation: | none |
Shipment: | |
Grid number: | 499 |
Position in grid: | 15 |
Arrival for irradiation: | 30. Oct 2017 |
Sent for analysis after irradiation: | 17. Nov 2017 |
Return for assembly: | none |
Irradiation: | |
Date: | 16. Nov 2017 |
Dose used: | 45 Gy |
Temperature: | 20 °C |
Position: | 4 |
Bias voltage: | 390.4 V (connected) |
Annealing: | |
Date: | none |
Temperature: | none |
Duration: | none |
Measurement results: | |
Voltage for Gain 100: | T = +20 °C: 391.0355534 V T = -25 °C: 354.8205027 V |
Voltage for Gain 150: | T = +20 °C: 398.9665725 V T = -25 °C: 362.3769013 V |
Voltage for Gain 200: | T = +20 °C: 403.3779987 V T = -25 °C: 366.6300789 V |
Gain/Voltage slope at M = 100: | T = +20 °C: 4.551833551 V-1 T = -25 °C: 4.875633323 V-1 |
Gain/Voltage slope at M = 150: | T = +20 °C: 8.934421953 V-1 T = -25 °C: 8.943380545 V-1 |
Gain/Voltage slope at M = 200: | T = +20 °C: 13.84525128 V-1 T = -25 °C: 15.61315316 V-1 |
Break-through voltage: | T = +20 °C: 419.1287378 V T = -25 °C: 382.4994951 V |
Notes: |
Version history
Time | Author | Change comment |
---|---|---|
05. Feb 2021 11:27:42 CET | jreher | Updated box and position via API. |
11. Aug 2020 17:58:06 CEST | jreher | Updated APD characteristics via API. |
21. Jul 2020 14:44:12 CEST | jreher | Updated APD location via API. |
21. Jul 2020 14:44:03 CEST | jreher | Updated box and position via API. |
19. Dec 2019 16:33:47 CET | spankonin | Updated APD batch assignment via API. |
19. Dec 2019 15:18:31 CET | jreher | Updated box and position via API. |
17. Nov 2017 09:40:11 CET | markus.moritz | Entered shipped after irradiation date. |
17. Nov 2017 09:38:00 CET | markus.moritz | Entered irradiation information. |
09. Nov 2017 15:10:57 CET | markus.moritz | Entered arrival for irradiation date. |
02. Nov 2017 15:16:53 CET | Tobias | Assigned to grid via information extracted from APD DB. |
23. Jun 2016 11:42:17 CEST | Tobias | Imported from Hamamatsu datasheet. |