Show Hamamatsu Avalanche Photo Diode 1702018509 - Archived data from Thu, 04. July 2019 11:11:51 CEST
This is all the information about APD 1702018509. If it is wrong, edit the data.
Subdetector specification: | |
---|---|
Serial: | 1702018509 |
Type: | Hamamatsu Avalanche Photo Diode |
Detector: | unassigned |
Unit: | unassigned |
Preamp: | 0 |
Current location: | Bochum Box 46 |
Installation information: | |
Label: | none |
Manufacturer information: | |
Wafer position: | E08 |
Break-through voltage: | 423 V |
Voltage for Gain 100 (T=+25°C): | 394.2 V |
Dark current: | 3.9 nA |
Screening Logistics: | |
Available: | Yes |
Storage Box: | 46 |
Position in Box: | 5 |
EP1 batch: | none |
EP1 batch after irradiation: | none |
Shipment: | |
Grid number: | 3003 |
Position in grid: | 10 |
Arrival for irradiation: | 11. Aug 2016 |
Sent for analysis after irradiation: | 02. Sep 2016 |
Return for assembly: | 13. Oct 2016 |
Irradiation: | |
Date: | 23. Aug 2016 |
Dose used: | 30 Gy |
Temperature: | 25 °C |
Position: | 4 |
Bias voltage: | 350 V (not connected) |
Annealing: | |
Date: | 24. Aug 2016 |
Temperature: | 80 °C |
Duration: | 10 h |
Measurement results: | |
Voltage for Gain 100: | T = +20 °C: none T = -25 °C: none |
Voltage for Gain 150: | T = +20 °C: none T = -25 °C: none |
Voltage for Gain 200: | T = +20 °C: none T = -25 °C: none |
Gain/Voltage slope at M = 100: | T = +20 °C: none T = -25 °C: none |
Gain/Voltage slope at M = 150: | T = +20 °C: none T = -25 °C: none |
Gain/Voltage slope at M = 200: | T = +20 °C: none T = -25 °C: none |
Break-through voltage: | T = +20 °C: none T = -25 °C: none |
Notes: |
Version history
Time | Author | Change comment |
---|---|---|
05. Feb 2021 10:54:04 CET | jreher | Updated box and position via API. |
03. Feb 2021 18:19:51 CET | jreher | Updated box and position via API. |
07. Oct 2020 15:46:07 CEST | jreher | Updated APD location via API. |
11. Aug 2020 17:27:09 CEST | jreher | Updated APD characteristics via API. |
27. Nov 2019 19:37:08 CET | jreher | Updated APD location via API. |
25. Nov 2019 17:14:32 CET | jreher | Updated box and position via API. |
04. Jul 2019 11:11:51 CEST | jreher | Updated APD location via API. |
18. Jun 2019 13:30:06 CEST | jgrochowski | Updated APD batch assignment via API. |
05. Apr 2018 14:04:48 CEST | jgrochowski | |
13. Oct 2016 11:47:56 CEST | markus.moritz | Entered return for assembly date. |
08. Sep 2016 13:37:08 CEST | markus.moritz | Entered shipped after irradiation date. |
24. Aug 2016 14:39:19 CEST | christopher.l.hahn | Entered irradiation information. |
24. Aug 2016 14:26:21 CEST | christopher.l.hahn | Entered annealing information. |
11. Aug 2016 11:49:37 CEST | markus.moritz | Entered arrival for irradiation date. |
01. Aug 2016 17:52:14 CEST | Tobias | Assigned to grid via information extracted from APD DB. |
23. Jun 2016 11:42:14 CEST | Tobias | Imported from Hamamatsu datasheet. |