RUB » Physics » The Faculty » Chairs and Working Groups » EP1 » PANDA FEMC Production Database

Grid Overview

Grid specification:  
Grid number: 694
Number of APDs: 19
   
Grid information:  
Arrival for irradiation: 11. Aug 2016
Date of irradiation: 23. Aug 2016
Irradiation temperature: 25 °C
Irradiation voltage: 350 V
Irradiation dose: 30 Gy
Irradiation position: 4
Shipped for annealing/analysis: 02. Sep 2016
Annealing date: 24. Aug 2016
Annealing temperature: 80 °C
Annealing duration: 10 h
Return for assembly: 15. Nov 2016
Operations: Enter irradiation dataEnter annealing dataEnter shipment data
   
Grid overview:  
Slot 0: 2313025218 (HV connected)
Slot 1: 2313025219 (HV connected)
Slot 2: 2313025220 (HV connected)
Slot 3: 2313025222 (HV connection unknown)
Slot 4: 2313025223 (HV connection unknown)
Slot 5: 2313025224 (HV connection unknown)
Slot 6: 2313025225 (HV connected)
Slot 7: 2313025226 (HV connected)
Slot 8: 2313025227 (HV connected)
Slot 9: 2313025228 (HV connected)
Slot 10: 2313025229 (HV connected)
Slot 11: 2313025230 (HV connected)
Slot 12: 2313025231 (HV connected)
Slot 13: 2313025232 (HV connected)
Slot 14: 2313025233 (HV connected)
Slot 15: 2313025234 (HV connected)
Slot 16: 2313025235 (HV connected)
Slot 17: 2313025236 (HV connected)
Slot 18: empty
Slot 19: 2313025238 (HV connection unknown)