Grid Overview
Grid specification: | |
---|---|
Grid number: | 313 |
Number of APDs: | 17 |
Grid information: | |
Arrival for irradiation: | 02. Nov 2016 |
Date of irradiation: | 04. Nov 2016 |
Irradiation temperature: | 20 °C |
Irradiation voltage: | 350 V |
Irradiation dose: | 30 Gy |
Irradiation position: | 1 |
Shipped for annealing/analysis: | 10. Nov 2016 |
Annealing date: | none |
Annealing temperature: | none |
Annealing duration: | none |
Return for assembly: | 09. Dec 2016 |
Operations: | Enter irradiation data • Enter annealing data • Enter shipment data |
Grid overview: | |
Slot 0: | 1308014090 (HV connected) |
Slot 1: | 1308014091 (HV connected) |
Slot 2: | 1308014092 (HV connected) |
Slot 3: | empty |
Slot 4: | 1308014095 (HV connected) |
Slot 5: | 1308014096 (HV connected) |
Slot 6: | 1308014097 (HV connected) |
Slot 7: | 1308014098 (HV connected) |
Slot 8: | 1308014100 (HV connected) |
Slot 9: | 1308014102 (HV connected) |
Slot 10: | empty |
Slot 11: | empty |
Slot 12: | 1308014105 (HV connected) |
Slot 13: | 1308014107 (HV connected) |
Slot 14: | 1308014108 (HV connected) |
Slot 15: | 1308014109 (HV connected) |
Slot 16: | 1308014110 (HV connected) |
Slot 17: | 1308014111 (HV connected) |
Slot 18: | 1308014112 (HV connected) |
Slot 19: | 1308014113 (HV connected) |